NDAC 33.1-10-06-02
Definitions
Cite as N.D. Admin. Code ยง 33.1-10-06-02
As used in this chapter, the following definitions apply:
1.
"Absorbed dose" means the energy imparted by ionizing radiation per unit mass of irradiated
material. The units of absorbed dose are the gray (Gy) and the rad.
2.
"Accessible surface" means surface of equipment or of an equipment part that can be touched
by persons without the use of a tool.
3.
"Added filtration" means any filtration which is in addition to the inherent filtration.
4.
"Air kerma" means kerma in air (see "kerma").
5.
"Air kerma rate" means the air kerma per unit of time.
6.
"AKR" means air kerma rate.
7.
"Allied health" means occupations of medical personnel who are not physicians and are
qualified by special training to undergo cross-training into x-ray as a limited x-ray machine
operator. Refer to appendix G for qualifying professions.
8.
"Aluminum equivalent" means the thickness of type 1100 aluminum alloy affording the same
attenuation, under specified conditions, as the material in question. (The nominal chemical
composition of type 1100 aluminum alloy is ninety-nine percent minimum aluminum,
twelve-hundredths percent copper.)
9.
"As low as reasonably achievable" (ALARA) means making every reasonable effort to
maintain the exposures to radiation as far below dose limits as is practicable.
10.
"Assembler" means any person engaged in the business of assembling, replacing, or installing
one or more components into an x-ray system or subsystem. The term includes the owner of
an x-ray system or the employee or agent who assembles components into an x-ray system
that is subsequently used to provide professional or commercial services.
11.
"Attenuation block" means a block or stack, having dimensions twenty centimeters by twenty
centimeters by three and eight-tenths centimeters, of type 1100 aluminum alloy or other
materials having equivalent attenuation.
12.
"Automatic exposure control" means a device which automatically controls one or more
technique factors in order to obtain at a preselected location or locations a required quantity of
radiation (includes devices such as phototimers and ion chambers).
13.
"Barrier" (see "protective barrier").
14.
"Beam axis" means the axis of rotation of the beam-limiting device from the source through
the centers of the x-ray fields.
15.
"Beam-limiting device" means a device which provides a means to restrict the dimensions of
the useful beam.
16.
"Biennium" means a two-year cycle.
17.
"Board certified" means an individual who has completed an accredited school of medical
radiography or chiropractic radiography and has passed a national registry examination.
18.
"Board eligible" means an individual who has obtained eligibility to take a national registry
examination in radiologic technology or chiropractic radiologic technology.
19.
"Bone densitometry system" means a medical device which uses electronically produced
ionizing radiation to determine the density of bone structures of human patients.
20.
"Calibration" means the determination of:
a.
The response or reading of an instrument relative to a series of known radiation values
over the range of the instrument; or
b.
The strength of a source of radiation relative to a standard.
21.
"C-arm x-ray system" means an x-ray system in which the image receptor and x-ray tube
housing assembly are connected by a common mechanical support system in order to
maintain a desired spatial relationship. This system is designed to allow a change in the
projection of the beam through the patient without a change in the position of the patient.
22.
"Cephalometric device" means a device intended for the radiographic visualization and
measurement of the dimensions of the human head.
23.
"Certified components" means components of x-ray systems which are subject to regulations
promulgated under the Radiation Control for Health and Safety Act of 1968 [Pub. L. 90-602].
24.
"Certified system" means any x-ray system which has one or more certified component or
components.
25.
"CEU" (see "continuing education unit").
26.
"CFR" means Code of Federal Regulations.
27.
"Changeable filters" means any filter, exclusive of inherent filtration, which can be removed
from the useful beam through any electronic, mechanical, or physical process.
28.
"Coefficient of variation" or "C" means the ratio of the standard deviation to the mean value of
a set of observations. It is estimated using the following equation:
where:
s
=
Estimated standard deviation of the population.
=
Mean value of observations in sample.
Xi
=
ith observation in sample.
n
=
Number of observations in sample.
29.
"Computed tomography" means the production of a tomogram by the acquisition and
computer processing of x-ray transmission data.
30.
"Contact therapy system" means an x-ray system used for therapy with the x-ray tube port
placed in contact with or within five centimeters of the surface being treated.
31.
"Continuing education" means a planned, organized, and administered learning activity that
enhances the knowledge and underlying skills of an x-ray operator.
32.
"Continuing education unit" means a unit of measure for continuing education. One continuing
education unit is equal to one contact hour.
33.
"Control panel" means that part of the x-ray control upon which are mounted the switches,
knobs, pushbuttons, and other hardware necessary for manually setting the technique factors.
34.
"Cooling curve" means the graphical relationship between heat units stored and cooling time.
35.
"CT" (see "computed tomography").
36.
"Dead-man switch" means a switch so constructed that a circuit closing contact can be
maintained only by continuous pressure on the switch by the operator.
37.
"Department" means the department of environmental quality.
38.
"Detector" (see "radiation detector").
39.
"Diagnostic source assembly" means the tube housing assembly with a beam-limiting device
attached.
40.
"Diagnostic x-ray imaging system" means an assemblage of components for the generation,
emission, and reception of x-rays and the transformation, storage, and visual display of the
resultant x-ray image.
41.
"Diagnostic x-ray system" means an x-ray system designed for irradiation of any part of the
human or animal body for the purpose of diagnosis or visualization.
42.
"Direct scattered radiation" means that scattered radiation which has been deviated in
direction only by materials irradiated by the useful beam (see "scattered radiation").
43.
"Direct supervision" requires direct observation and observer must be in the room during the
time the x-ray image is obtained.
44.
"Dose" is a generic term that means absorbed dose, dose equivalent, effective dose
equivalent, committed dose equivalent, committed effective dose equivalent, total organ dose
equivalent, or total effective dose equivalent. For purposes of these rules, "radiation dose" is
an equivalent term.
45.
"Dose limits" means the permissible upper bounds of radiation of doses established in
accordance with these rules.
46.
"Entrance exposure rate" means the radiation exposure free in air per unit time at the point
where the center of the useful beam enters the patient.
47.
"Equipment" (see "x-ray equipment").
48.
"Exposure" means being exposed to ionizing radiation.
49.
"Field emission equipment" means equipment which uses an x-ray tube in which electron
emission from the cathode is due solely to the action of an electric field.
50.
"Filter" means material placed in the useful beam to absorb preferentially selected radiations.
51.
"Fluoroscopic imaging assembly" means a subsystem in which x-ray photons produce a
visible image. It includes the image receptor or receptors such as the image intensifier and
spot-film device, electrical interlocks, if any, and structural material providing linkage between
the image receptor and diagnostic source assembly.
52.
"Focal spot" means the location projected on the anode of the x-ray tube bombarded by the
electrons accelerated from the cathode and from which the useful beam originates.
53.
"General diagnostic operator" means an individual who is American registry of radiologic
technologists (ARRT) or American chiropractic registry of radiologic technologists (ACRRT)
board certified, is or has been board eligible, or has the equivalent educational and clinical
training and received specific authorization from the department.
54.
"General purpose radiographic x-ray system" means any radiographic x-ray system which, by
design, is not limited to radiographic examination of specific anatomical regions.
55.
"Gonad shield" means a protective barrier for the testes or ovaries.
56.
"Gray" (Gy) means the SI unit of absorbed dose. One gray is equal to an absorbed does of
one joule per kilogram or 100 rad.
57.
"Half-value layer" means the thickness of specified material which attenuates x-radiation or
gamma radiation to an extent such that the air kerma rate, exposure rate or absorbed dose
rate is reduced to one-half of the value measured without the material at the same point.
58.
"Hand-held dental x-ray equipment" (see "x-ray equipment").
59.
"Healing arts" means diagnostic or healing treatment of human and animal maladies, including
the following which are duly licensed by the state of North Dakota for the lawful practice of
medicine and its associated specialties, dentistry, veterinary medicine, osteopathy,
chiropractic, and podiatry.
60.
"Healing arts screening" means the testing of human beings using x-ray machines for the
detection or evaluation of health indications when such tests are not specifically and
individually ordered by a licensed practitioner of the healing arts legally authorized to
prescribe such x-ray tests for the purpose of diagnosis or treatment.
61.
"Heat unit" means a unit of energy equal to the product of the peak kilovoltage, milliamperes,
and seconds, i.e., kVp x mA x seconds.
62.
"HVL" (see "half-value layer").
63.
"Image intensifier" means a device, installed in its housing, which instantaneously converts an
x-ray pattern into a corresponding light image of higher energy density.
64.
"Image receptor" means any device, such as a fluorescent screen or radiographic film, which
transforms incident x-ray photons either into a visible image or into another form which can be
made into a visible image by further transformations.
65.
"Image receptor support" means, for mammographic systems, that part of the system
designed to support the image receptor during a mammographic examination.
66.
"Inherent filtration" means the filtration of the useful beam provided by the permanently
installed components of the tube housing assembly.
67.
"Inspection" means an official examination or observation, including tests, surveys, and
monitoring to determine compliance with rules, regulations, requirements, and conditions of
the department.
68.
"Irradiation" means the exposure of matter to ionizing radiation.
69.
"Kerma" means the sum of the initial kinetic energies of all the charged ionizing particles
liberated by uncharged ionizing particles per unit mass of a specified material. The SI unit of
measure is joule per kilogram, or gray (Gy).
70.
"Kilovolts peak" (see "peak tube potential").
71.
"kV" means kilovolts.
72.
"kVp" (see "peak tube potential").
73.
"kWs" means kilowatt second. It is equivalent to 103 kV . mA . s, i.e.,
kWs = (X)kV x (Y)mA x (Z)s x 10-3
= XYZ
103
74.
"Lead equivalent" means the thickness of lead affording the same attenuation, under specified
conditions, as the material in question.
75.
"Leakage radiation" means radiation emanating from the diagnostic or therapeutic source
assembly except for:
a.
The useful beam; and
b.
Radiation produced when the exposure switch or timer is not activated.
76.
"Leakage technique factors" means the technique factors associated with the diagnostic or
therapeutic assembly which are used in measuring leakage radiation. They are defined as
follows:
a.
For diagnostic source assemblies intended for capacitor energy storage equipment, the
maximum-rated peak tube potential and the maximum-rated number of exposures in an
hour for operation at the maximum-rated peak tube potential with the quantity of charge
per exposure being ten millicoulombs, i.e., ten milliampere seconds, or the minimum
obtainable from the unit, whichever is larger.
b.
For diagnostic source assemblies intended for field emission equipment rated for pulsed
operation, the maximum-rated peak tube potential and the maximum-rated number of
x-ray pulses in an hour for operation at the maximum-rated peak tube potential.
c.
For all other diagnostic or therapeutic source assemblies, the maximum-rated peak tube
potential and the maximum-rated continuous tube current for the maximum-rated peak
tube potential.
77.
"Light field" means the area illuminated by light, simulating the radiation field.
78.
"Limited x-ray machine operator" means any individual who has completed the necessary
didactic and clinical training required to perform limited scope x-ray procedures.
79.
"Linear attenuation coefficient" or "u" means the quotient of dN/N divided by dl when dN/N is
the fraction of uncharged ionizing radiation that experience interactions in traversing a
distance dl in a specified material.
80.
"mA" means milliampere.
81.
"mAs" means milliampere second.
82.
"Milliampere" as used in this chapter applies to x-ray tube current.
83.
"Milliampere second" as used in this chapter is the product of the tube current and x-ray
exposure time measured in seconds.
84.
"Mobile x-ray equipment" (see "x-ray equipment").
85.
"Monitoring" means the measurement of radiation and the use of the measured results to
evaluate potential exposures and doses.
86.
"Patient" means an individual or animal subjected to radiation for the purposes of diagnosis or
treatment.
87.
"PBL" has the same meaning as "positive beam limitation".
88.
"Peak tube potential" means the maximum value of the potential difference across the x-ray
tube during an exposure.
89.
"Phantom" means a volume of material behaving in a manner similar to tissue with respect to
the absorption and scattering of the ionizing radiation in question.
90.
"Phototimer" means a method for controlling radiation exposures to image receptors by the
amount of radiation which reaches a radiation monitoring device. The radiation monitoring
device is part of an electronic circuit which controls the duration of time the tube is activated
(see "automatic exposure control").
91.
"Physician" means a medical doctor, doctor of osteopathy, doctor of podiatry, or chiropractor
licensed by a state or territory of the United States, the District of Columbia, or the
Commonwealth of Puerto Rico.
92.
"Portable x-ray equipment" (see "x-ray equipment").
93.
"Position indicating device" means a device on dental x-ray equipment used to indicate the
beam position and to establish a definite source surface (skin) distance. It may or may not
incorporate or serve as a beam-limiting device.
94.
"Positive beam limitation" means the automatic or semiautomatic adjustment of an x-ray beam
to the size of the selected image receptor, whereby exposures cannot be made without such
adjustment.
95.
"Primary dose monitoring system" means a system which will monitor the useful beam during
irradiation and which will terminate irradiation when a preselected number of dose monitor
units have been delivered.
96.
"Primary protective barrier" (see "protective barrier").
97.
"Protective apron" means an apron made of radiation attenuating materials used to reduce
radiation exposure.
98.
"Protective barrier" means a barrier of radiation absorbing material or materials used to reduce
radiation exposure. The types of protective barriers are as follows:
a.
"Primary protective barrier" means the material, excluding filters, placed in the useful
beam; and
b.
"Secondary protective barrier" means the material which attenuates stray radiation.
99.
"Protective glove" means a glove made of radiation absorbing materials used to reduce
radiation exposure.
100.
"Qualified expert" means an individual having the knowledge, training, and experience to
measure ionizing radiation, to evaluate safety techniques, and to advise regarding radiation
protection needs, for example, individuals certified in the appropriate field by the American
board of radiology, or the American board of health physics, or the American board of medical
physics, or those having equivalent qualifications. With reference to the calibration of radiation
therapy equipment, "qualified expert" means an individual having, in addition to the above
qualifications, training and experience in the clinical applications of radiation physics to
radiation therapy, for example, individuals certified in therapeutic radiological physics or x-ray
and radium physics by the American board of radiology, or those having equivalent
qualifications.
101.
"Radiation" means x-rays and gamma rays, which are capable of producing ions. For
purposes of this chapter, ionizing radiation is an equivalent term.
102.
"Radiation detector" means a device which in the presence of radiation provides a signal or
other indication suitable for use in measuring one or more quantities of incident radiation.
103.
"Radiation exposure" means the quotient of dQ by dm where "dQ" is the absolute value of the
total charge of the ions of one sign produced in air when all the electrons (negatrons and
positrons) liberated by photons in a volume element of air having mass "dm" are completely
stopped in air. The SI unit of radiation exposure is the coulomb per kilogram (C/kg). (See
section 33.1-10-01-14 units of exposure, dose, and activity for the special unit equivalent
"roentgen" (R).)
104.
"Radiation exposure rate" means the radiation exposure per unit of time, such as R/min,
mR/h, etc.
105.
"Radiation machine" means any device capable of producing radiation except those devices
with radioactive material as the only source of radiation.
106.
"Radiation therapy simulation system" means a radiographic, fluoroscopic, or computed
tomography x-ray system intended for localizing the volume to be exposed during radiation
therapy and confirming the position and size of the therapeutic irradiation field.
107.
"Radiograph" means an image receptor on which the image is created directly or indirectly by
an x-ray pattern and results in a permanent record.
108.
"Radiographic imaging system" means any system whereby a permanent or temporary image
is recorded on an image receptor by the action of ionizing radiation.
109.
"Radiological physicist" means an individual who:
a.
Is certified by the American board of radiology in therapeutic radiological physics,
radiological physics, or x-ray and gamma-ray physics;
b.
Has a bachelor's degree in one of the physical sciences or engineering and three year's
full-time experience working in therapeutic or diagnostic radiological physics under the
direction of a physicist certified by the American board of radiology. The work duties must
include duties involving the calibration and spot checks of a medical accelerator or a
sealed source teletherapy unit; or
c.
Has a master's or a doctor's degree in physics, biophysics, radiological physics, health
physics, or engineering; has had one year's full-time training in therapeutic or diagnostic
radiological physics; and has had one year's full-time work experience in a radiotherapy
facility where the individual's duties involve calibration and spot checks of a medical
accelerator or a sealed source teletherapy unit.
110.
"Rating" means the operating limits as specified by the component manufacturer.
111.
"Recording" means producing a permanent form of an image resulting from x-ray photons.
112.
"Registrant" means any person, group, or facility who is registered with the department and is
legally obligated to register with the department pursuant to North Dakota Century Code
chapter 23.1-02.
113.
"Roentgen" or "(R)" means the special unit of exposure. One roentgen equals two hundred
fifty-eight millionth of a coulomb per kilograph of air.
114.
"Scattered radiation" means radiation that, during passage through matter, has been deviated
in direction (see "direct scattered radiation").
115.
"Secondary dose monitoring system" means a system which will terminate irradiation in the
event of failure of the primary dose monitoring system.
116.
"Secondary protective barrier" (see "protective barrier").
117.
"Shutter" means a device attached to the tube housing assembly which can intercept the
entire cross-sectional area of the useful beam and which has a lead equivalency not less than
that of the tube housing assembly.
118.
"SI" means the abbreviation for the international system of units.
119.
"SID" has the same meaning as "source-image receptor distance".
120.
"Source" means the location or material, or both, from which the radiation emanates.
121.
"Source-image receptor distance" means the distance from the source to the center of the
input surface of the image receptor.
122.
"Spot check" means a procedure which is performed to assure that a previous calibration
continues to be valid.
123.
"Spot film" means a radiograph which is made during a fluoroscopic examination to
permanently record conditions which exist during that fluoroscopic procedure.
124.
"Spot-film device" means a device intended to transport or position a radiographic image
receptor between the x-ray source and fluoroscopic image receptor. It includes a device
intended to hold a cassette over the input end of an image intensifier for the purpose of
making a radiograph.
125.
"Stationary x-ray equipment" (see "x-ray equipment").
126.
"Stray radiation" means the sum of leakage and scattered radiation.
127.
"Survey" means an evaluation of the radiological conditions which may include tests, physical
examinations, and measurements of levels of radiation.
128.
"Technique factors" means the conditions of operation. They are specified as follows:
a.
For capacitor energy storage equipment, peak tube potential in kilovolts and quantity of
charge in milliampere second.
b.
For field emission equipment rated for pulsed operation, peak tube potential in kilovolts
and number of x-ray pulses.
c.
For CT x-ray systems designed for pulsed operation, peak tube potential in kilovolts,
scan time in seconds, and either tube current in milliampere, x-ray pulse width in
seconds, and the number of x-ray pulses per scan, or the product of tube current, x-ray
pulse width, and the number of x-ray pulses in milliampere second.
d.
For CT x-ray systems not designed for pulsed operation, peak tube potential in kilovolts,
and either tube current in milliampere and scan time in seconds, or the product of tube
current and exposure time in milliampere second and the scan time when the scan time
and exposure time are equivalent.
e.
For all other equipment, peak tube potential in kilovolt and either tube current in
milliampere and exposure time in seconds, or the product of tube current and exposure
time in milliampere second.
129.
"Termination of irradiation" means the stopping of irradiation in a fashion which will not permit
continuance of irradiation without the resetting of operating conditions at the control panel.
130.
"Tomogram" means the depiction of x-ray attenuation properties of a section through the body.
131.
"Traceable to a national standard" means that a quantity or a measurement has been
compared to a national standard directly or indirectly through one or more intermediate steps
and that all comparisons have been documented.
132.
"Tube" means an x-ray tube, unless otherwise specified.
133.
"Tube housing assembly" means the tube housing with tube installed. It includes high-voltage
or filament transformers, or both, and other appropriate elements when such are contained
within the tube housing.
134.
"Tube rating chart" means the set of curves which specify the rated limits of operation of the
tube in terms of the technique factors.
135.
"Useful beam" means the radiation emanating from the tube housing port or the radiation head
and passing through the aperture of the beam limiting device when the exposure controls are
in a mode to cause the system to produce radiation.
136.
"Variable-aperture beam-limiting device" means a beam-limiting device which has capacity for
stepless adjustment of the x-ray field size at a given source-image receptor distance.
137.
"Visible area" means that portion of the input surface of the image receptor over which
incident x-ray photons are producing a visible image.
138.
"Wedge filter" means an added filter effecting continuous progressive attenuation on all or part
of the useful beam.
139.
"Whole body" means for purposes of external exposure, head, trunk including male gonads,
arms above the elbows, or legs below the knees.
140.
"X-ray exposure control" means a device, switch, button, or other similar means by which the
operator initiates or terminates, or both, the radiation exposure. It may include equipment such
as timers, phototimers, automatic brightness stabilizers, and similar devices.
141.
"X-ray equipment" means an x-ray system, subsystem, or component thereof. Types of x-ray
equipment are as follows:
a.
"Hand-held dental x-ray equipment" means any dental x-ray equipment which is
designated to be physically held during x-ray exposure.
b.
"Mobile x-ray equipment" means x-ray equipment mounted on a permanent base with
wheels or casters for moving while completely assembled.
c.
"Portable x-ray equipment" means x-ray equipment designed to be hand-carried.
d.
"Stationary x-ray equipment" means x-ray equipment which is installed in a fixed location.
142.
"X-ray field" means that area of the intersection of the useful beam and any one of the set of
planes parallel to and including the plane of the image receptor, whose perimeter is the locus
of points at which the radiation exposure rate is one-fourth of the maximum in the intersection.
143.
"X-ray high-voltage generator" means a device which transforms electrical energy from the
potential supplied by the x-ray control to the tube operating potential. The device may also
include means for transforming alternating current to direct current, filament transformers for
the x-ray tube, high-voltage switches, electrical protective devices, and other appropriate
elements.
144.
"X-ray system" means an assemblage of components for the controlled production of x-rays. It
includes minimally an x-ray high-voltage generator, an x-ray control, a tube housing assembly,
a beam-limiting device, and the necessary supporting structures. Additional components which
function with the system are considered integral parts of the system.
145.
"X-ray tube" means any electron tube which is designed for the conversion of electrical energy
into x-ray energy.