NDAC 33.1-24-02-209
Recordkeeping requirements
Cite as N.D. Admin. Code § 33.1-24-02-209
1.
Each remanufacturer or other person that stores or treats the hazardous secondary material
subject to requirements of sections 33.1-24-02-200 through 33.1-24-02-214 shall record and
maintain the information specified in subsections 2 through 10, as applicable to the facility.
Except for air emission control equipment design documentation and information required by
subsections 9 and 10, records required by this section must be maintained at the facility for a
minimum of three years. Air emission control equipment design documentation must be
maintained at the facility until the air emission control equipment is replaced or otherwise no
longer in service. Information required by subsections 9 and 10 must be maintained at the
facility for as long as the hazardous secondary material management unit is not using air
emission controls specified in sections 33.1-24-02-204 through 33.1-24-02-207 in accordance
with the conditions specified in subsection 4 or subdivision g of subsection 2 of section
33.1-24-02-200, respectively.
2.
The remanufacturer or other person that stores or treats the hazardous secondary material
using a tank with air emission controls in accordance with the requirements of section
33.1-24-02-204 shall prepare and maintain records for the tank that include the following
information:
a.
For each tank using air emission controls in accordance with the requirements of section
33.1-24-02-204, the remanufacturer or other person that stores or treats the hazardous
secondary material shall record:
(1)
A tank identification number (or other unique identification description as selected by
the remanufacturer or other person that stores or treats the hazardous secondary
material).
(2)
A record for each inspection required by section 33.1-24-02-204 which includes the
following information:
(a)
Date inspection was conducted.
(b)
For each defect detected during the inspection: the location of the defect, a
description of the defect, the date of detection, and corrective action taken to
repair the defect. If repair of the defect is delayed in accordance with the
requirements of section 33.1-24-02-204, the remanufacturer or other person
that stores or treats the hazardous secondary material also shall record the
reason for the delay and the date that completion of repair of the defect is
expected.
b.
In addition to the information required by subdivision a, the remanufacturer or other
person that stores or treats the hazardous secondary material shall record the following
information, as applicable to the tank:
(1)
The remanufacturer or other person that stores or treats the hazardous secondary
material using a fixed roof to comply with the tank level 1 control requirements
specified in subsection 3 of section 33.1-24-02-204 shall prepare and maintain
records for each determination for the maximum organic vapor pressure of the
hazardous secondary material in the tank performed in accordance with the
requirements of subsection 3 of section 33.1-24-02-204. The records must include
the date and time the samples were collected, the analysis method used, and the
analysis results.
(2)
The remanufacturer or other person that stores or treats the hazardous secondary
material using an internal floating roof to comply with the tank level 2 control
requirements specified in subsection 5 of section 33.1-24-02-204 shall prepare and
maintain documentation describing the floating roof design.
(3)
Remanufacturers or other persons that store or treat the hazardous secondary
material using an external floating roof to comply with the tank level 2 control
requirements specified in subsection 6 of section 33.1-24-02-204 shall prepare and
maintain the following records:
(a)
Documentation describing the floating roof design and the dimensions of the
tank.
(b)
Records for each seal gap inspection required by subdivision c of subsection 6
of section 33.1-24-02-204 describing the results of the seal gap
measurements. The records must include the date that the measurements
were performed, the raw data obtained for the measurements, and the
calculations of the total gap surface area. If the seal gap measurements do not
conform to the specifications in subdivision a of subsection 6 of section
33.1-24-02-204, the records must include a description of the repairs that were
made, the date the repairs were made, and the date the tank was emptied, if
necessary.
(4)
Each remanufacturer or other person that stores or treats the hazardous secondary
material using an enclosure to comply with the tank level 2 control requirements
specified in subsection 9 of section 33.1-24-02-204 shall prepare and maintain the
following records:
(a)
Records for the most recent set of calculations and measurements performed
by the remanufacturer or other person that stores or treats the hazardous
secondary material to verify that the enclosure meets the criteria of a
permanent total enclosure as specified in "Procedure T - Criteria for and
Verification of a Permanent or Temporary Total Enclosure" under 40 CFR
52.741, appendix B.
(b)
Records required for the closed-vent system and control device in accordance
with the requirements of subsection 5.
3.
[Reserved].
4.
The remanufacturer or other person that stores or treats the hazardous secondary material
using containers with container level 3 air emission controls in accordance with the
requirements of section 33.1-24-02-206 shall prepare and maintain records that include the
following information:
a.
Records for the most recent set of calculations and measurements performed by the
remanufacturer or other person that stores or treats the hazardous secondary material to
verify that the enclosure meets the criteria of a permanent total enclosure as specified in
"Procedure T - Criteria for and Verification of a Permanent or Temporary Total Enclosure"
under 40 CFR 52.741, appendix B.
b.
Records required for the closed-vent system and control device in accordance with the
requirements of subsection 5.
5.
The remanufacturer or other person that stores or treats the hazardous secondary material
using a closed-vent system and control device in accordance with the requirements of section
33.1-24-02-207 shall prepare and maintain records that include the following information:
a.
Documentation for the closed-vent system and control device which includes:
(1)
Certification that is signed and dated by the remanufacturer or other person that
stores or treats the hazardous secondary material stating the control device is
designed to operate at the performance level documented by a design analysis as
specified in paragraph 2 or by performance tests as specified in paragraph 3 when
the tank or container is or would be operating at capacity or the highest level
reasonably expected to occur.
(2)
If a design analysis is used, then design documentation as specified in subdivision d
of subsection 2 of section 33.1-24-02-175. The documentation must include
information prepared by the remanufacturer or other person that stores or treats the
hazardous secondary material or provided by the control device manufacturer or
vendor that describes the control device design in accordance with paragraph 3 of
subdivision d of subsection 2 of section 33.1-24-02-175 and certification by the
remanufacturer or other person that stores or treats the hazardous secondary
material that the control equipment meets the applicable specifications.
(3)
If performance tests are used, then a performance test plan as specified in
subdivision c of subsection 2 of section 33.1-24-02-175 and all test results.
(4)
Information as required by subdivisions a and b of subsection 3 of section
33.1-24-02-175, as applicable.
(5)
A remanufacturer or other person that stores or treats the hazardous secondary
material shall record, on a semiannual basis, the information specified in
subparagraphs a and b for those planned routine maintenance operations that
would require the control device not to meet the requirements of paragraph 1, 2,
or 3 of subdivision a of subsection 3 of section 33.1-24-02-207, as applicable.
(a)
A description of the planned routine maintenance that is anticipated to be
performed for the control device during the next six-month period. This
description must include the type of maintenance necessary, planned
frequency of maintenance, and lengths of maintenance periods.
(b)
A description of the planned routine maintenance that was performed for the
control device during the previous six-month period. This description must
include the type of maintenance performed and the total number of hours
during those six months that the control device did not meet the requirements
of paragraph 1, 2, or 3 of subdivision a of subsection 3 of section
33.1-24-02-207, as applicable, due to planned routine maintenance.
(6)
A remanufacturer or other person that stores or treats the hazardous secondary
material shall record the information specified in subparagraphs a through c for
those unexpected control device system malfunctions that would require the control
device not to meet the requirements of paragraph 1, 2, or 3 of subdivision a of
subsection 3 of section 33.1-24-02-207, as applicable.
(a)
The occurrence and duration of each malfunction of the control device system.
(b)
The duration of each period during a malfunction when gases, vapors, or
fumes are vented from the hazardous secondary material management unit
through the closed-vent system to the control device while the control device is
not properly functioning.
(c)
Actions taken during periods of malfunction to restore a malfunctioning control
device to its normal or usual manner of operation.
(7)
Records of the management of carbon removed from a carbon adsorption system
conducted in accordance with paragraph 2 of subdivision c of subsection 3 of
section 33.1-24-02-207.
6.
The remanufacturer or other person that stores or treats the hazardous secondary material
using a tank or container exempted under the hazardous secondary material organic
concentration conditions specified in subsection 3 of section 33.1-24-02-202, shall prepare
and maintain at the facility records documenting the information used for each material
determination (for example, test results, measurements, calculations, and other
documentation). If analysis results for material samples are used for the material
determination, the remanufacturer or other person that stores or treats the hazardous
secondary material shall record the date, time, and location that each material sample is
collected in accordance with applicable requirements of section 33.1-24-02-203.
7.
A remanufacturer or other person that stores or treats the hazardous secondary material
designating a cover as "unsafe to inspect and monitor" pursuant to subsection 12 of section
33.1-24-02-204 or subsection 7 of section 33.1-24-02-205 shall record and keep at the facility
the following information: the identification numbers for hazardous secondary material
management units with covers that are designated as "unsafe to inspect and monitor," the
explanation for each cover stating why the cover is unsafe to inspect and monitor, and the
plan and schedule for inspecting and monitoring each cover.
8.
The remanufacturer or other person that stores or treats the hazardous secondary material
that is subject to sections 33.1-24-02-200 through 33.1-24-02-214 and to the control device
standards in 40 CFR part 60, subpart VV, or 40 CFR part 61, subpart V, may elect to
demonstrate compliance with the applicable sections of sections 33.1-24-02-200 through
33.1-24-02-214 by documentation either pursuant to sections 33.1-24-02-200 through
33.1-24-02-214, or pursuant to the provisions of 40 CFR part 60, subpart VV or 40 CFR
part 61, subpart V, to the extent that the documentation required by 40 CFR parts 60 or 61
duplicates the documentation required by this section.