NDAC 33.1-24-05-177
Design and operating requirements
Cite as N.D. Admin. Code § 33.1-24-05-177
1.
Any landfill that is not covered by subsection 3 must have a liner system for all portions of the
landfill (except for existing portions of such landfill). The liner system must have:
a.
A liner that is designed, constructed, and installed to prevent any migration of wastes out
of the landfill to the adjacent subsurface soil or ground water or surface water at any time
during the active life (including the closure period) of the landfill. The liner must be
constructed of materials that prevent wastes from passing into the liner during the active
life of the facility. The liner must be:
(1)
Constructed of materials that have appropriate chemical properties and sufficient
strength and thickness to prevent failure due to pressure gradients (including static
head and external hydrogeologic forces), physical contact with the waste or
leachate to which they are exposed, climatic conditions, the stress of installation,
and the stress of daily operation;
(2)
Placed upon a foundation or base capable of providing support to the liner and
resistance to pressure gradients above and below the liner to prevent failure of the
liner due to settlement, compression, or uplift; and
(3)
Installed to cover all surrounding earth likely to be in contact with the waste or
leachate; and
b.
A leachate collection and removal system immediately above the liner that is designed,
constructed, maintained, and operated to collect and remove leachate from the landfill.
The department will specify design and operating conditions in the permit to ensure that
the leachate depth over the liner does not exceed one foot [.3048 meter]. The leachate
collection and removal system must be:
(1)
Constructed of materials that are:
(a)
Chemically resistant to the waste managed in the landfill and the leachate
expected to be generated; and
(b)
Of sufficient strength and thickness to prevent collapse under the pressures
exerted by overlying wastes, waste cover materials, and by any equipment
used at the landfill; and
(2)
Designed and operated to function without clogging through the scheduled closure
of the landfill.
2.
The owner or operator will be exempted from the requirements of subsection 1 if the
department finds, based on a demonstration by the owner or operator, that alternative design
and operating practices, together with location characteristics, will prevent the migration of any
hazardous constituents (see section 33.1-24-05-50) into the ground water or surface water at
any future time. In deciding whether to grant an exemption, the department will consider:
a.
The nature and quantity of the waste;
b.
The proposed alternate design and operation;
c.
The hydrogeologic setting of the facility, including the attenuative capacity and thickness
of the liners and soils present between the landfill and ground water or surface water;
and
d.
All other factors which would influence the quality and mobility of the leachate produced
and the potential for it to migrate to ground water or surface water.
3.
The owner or operator of each new landfill unit on which construction commences after
January 19, 1992, each lateral expansion of a landfill unit on which construction commences
after July 29, 1992, and each replacement of an existing landfill unit that is to commence
reuse after July 29, 1992, must install two or more liners and a leachate collection and
removal system above and between such liners. "Construction commences" is as defined in
section 33.1-24-01-04 under "existing facility".
a.
Liner.
(1)
The liner system must include:
(a)
A top liner designed and constructed of materials (for example, a
geomembrane) to prevent the migration of hazardous constituents into such
liner during the active life and postclosure care period; and
(b)
A composite bottom liner, consisting of at least two components. The upper
component must be designed and constructed of materials (for example, a
geomembrane) to prevent the migration of hazardous constituents into this
component during the active life and postclosure care period. The lower
component must be designed and constructed of materials to minimize the
migration of hazardous constituents if a breach in the upper component were
to occur. The lower component must be constructed of at least three feet
[91.44 centimeters] of compacted soil material with a hydraulic conductivity of
no more than 1x10-7 centimeters per second.
(2)
The liners must comply with paragraphs 1, 2, and 3 of subdivision a of subsection 1.
b.
The leachate collection and removal system immediately above the top liner must be
designed, constructed, operated, and maintained to collect and remove leachate from the
landfill during the active life and postclosure care period. The department will specify
design and operating conditions in the permit to ensure that the leachate depth over the
liner does not exceed thirty centimeters [1 foot]. The leachate collection and removal
system must comply with paragraphs 3 and 4 of subdivision c.
c.
The leachate collection and removal system between the liners, and immediately above
the bottom composite liners in the case of multiple leachate collection and removal
systems, is also a leak detection system. This leak detection system must be capable of
detecting, collecting, and removing leaks of hazardous constituents at the earliest
practicable time through all areas of the top liner likely to be exposed to waste or
leachate during the active life and postclosure care period. The requirements for a leak
detection system in this subdivision are satisfied by installation of a system that is, at a
minimum:
(1)
Constructed with a bottom slope of one percent or more;
(2)
Constructed of granular drainage materials with a hydraulic conductivity of 1x10-2
centimeters per second or more and a thickness of twelve inches [30.5 centimeters]
or more; or constructed of synthetic or geonet drainage materials with a
transmissivity of 3x10-5 square meters per second or more;
(3)
Constructed of materials that are chemically resistant to the waste managed in the
landfill and the leachate expected to be generated, and of sufficient strength and
thickness to prevent collapse under the pressures exerted by overlying wastes,
waste cover materials, and equipment used at the landfill;
(4)
Designed and operated to minimize clogging during the active life and postclosure
care period; and
(5)
Constructed with sumps and liquid removal methods (for example, pumps) of
sufficient size to collect and remove liquids from the sump and prevent liquids from
backing up into the drainage layer. Each unit must have its own sump or sumps.
The design of each sump and removal system must provide a method for
measuring and recording the volume of liquids present in the sump and of liquids
removed.
d.
The owner or operator shall collect and remove pumpable liquids in the leak detection
system sumps to minimize the head on the bottom liner.
e.
The owner or operator of a leak detection system that is not located completely above
the seasonal high-water table must demonstrate that the operation of the leak detection
system will not be adversely affected by the presence of ground water.
4.
The department may approve alternative design or operating practices to those specified in
subsection 3 if the owner or operator demonstrates to the department that such design and
operating practices, together with location characteristics:
a.
Will prevent the migration of any hazardous constituent into the ground water or surface
water at least as effectively as the liners and leachate collection and removal systems
specified in subsection 3; and
b.
Will allow detection of leaks of hazardous constituents through the top liner at least as
effectively.
5.
The double-liner requirements set forth in subsection 3 may be waived by the department for
any monofill, if:
a.
The monofill contains only hazardous waste from foundry furnace emission controls or
metal casting molding sand and such wastes do not contain constituents which would
render the wastes hazardous for reasons other than the toxicity characteristics in section
33.1-24-02-14 with hazardous waste numbers D004 through D017; and
b.
Monofill liner.
(1)
Evidence of leaking.
(a)
The monofill has at least one liner for which there is no evidence that such liner
is leaking;
(b)
The monofill is located more than one-quarter mile from an "underground
source of drinking water" (as that term is defined in 40 CFR section 270.2); and
(c)
The monofill is in compliance with generally acceptable ground water
monitoring requirements for facilities with hazardous waste permits; or
(2)
The owner or operator demonstrates that the monofill is located, designed, and
operated so as to assure that there will be no migration of any hazardous
constituent into ground water or surface water at any future time.
6.
The owner or operator of any replacement landfill unit is exempt from subsection 3 if:
a.
The existing unit was constructed in compliance with the design standards of this article;
and
b.
There is no reason to believe that the liner is not functioning as designed.
7.
The owner or operator shall design, construct, operate, and maintain a run-on control system
capable of preventing flow onto the active portion of the landfill during peak discharge from at
least a twenty-five-year storm.
8.
The owner or operator shall design, construct, operate, and maintain a runoff management
system to collect and control at least the water volume resulting from a twenty-four-hour,
twenty-five-year storm.
9.
Collection and holding facilities (for example, tanks or basins) associated with run-on and
runoff control systems must be emptied or otherwise managed expeditiously after storms to
maintain design capacity of this system.
10.
If the landfill contains any particulate matter which may be subject to wind dispersal, the owner
or operator shall cover or otherwise manage the landfill to control wind dispersal.
11.
The department will specify in the permit all design and operating practices that are necessary
to ensure that the requirements of this section are satisfied.