OAC 310:681-8-3
Sampling requirements and procedures
Cite as Okla. Admin. Code § 310:681-8-3
General requirements.
(a) Samples must be collected in accordance with OAC 310:681-8-3(a)-
(c). Individuals collecting samples are called "Samplers."
(1) Samplers must:
(A) Follow the approved sampling policies and standard operating
procedures of the laboratory that will be testing the samples
collected. Samplers shall have access to a copy of the
laboratory’s standard operating procedures while they are
collecting the samples must be trained on how to collect samples
in accordance with the standard operating procedures of the
laboratory(ies) that will be conducting the testing on the
samples collected and shall have access to a copy of the
standard operating procedures while they are collecting the
samples; and
(B) Follow inventory manifest requirements set forth in these
Rules.
(2) Samplers shall collect samples at the location of the grower or
processor.
(3) A licensed laboratory must either utilize a licensed commercial
transporter to transport samples or obtain a commercial transporter
license in order to transport samples from the grower or processor
2021.06_OSDH681_OMMARulesChapterAsAmended
82
to the laboratory.
(4) All commercial transporters, growers, or processors transporting
samples to a laboratory shall be prohibited from storing samples at
any location other than the laboratory facility. All samples must be
delivered the day of collection.
(5) Samples shall only be collected from harvest batches and
production batches in final form. For purpose of this Subsection,
"final form" means the form medical marijuana or a medical marijuana
product is in when sold or transferred.
(6) The sampler shall collect both a primary sample and a reserve
sample from each harvest batch and production batch. The sample
shall be clearly and conspicuously labeled and the label shall
include at least the following information:
(A) Whether the sample is "Primary Sample" or "Reserve
Sample";
(B) Name and license number of grower or processor from whom
the sample was taken; and
(C) The batch number of harvest batch or production batch from
which the sample was taken.
(7) The primary sample and reserve sample shall be stored and
separately and analyzed separately. The reserve sample is used for
quality control purposes only.
(8) Samples shall be transported and subsequently stored at the
laboratory in a manner that prevents degradation, contamination, and
tampering. If the medical marijuana or medical marijuana product
specifies on the label how the product shall be stored, the
laboratory shall store the sample as indicated on the label.
(9) The sampler shall create and use a sample field log to record
the following information for each sample:
(A) Laboratory's name, address, and license number;
(B) Sampler's name(s) and title(s) and the names of others
onsite Title and version of the laboratory’s standard
operating procedure(s) followed when collecting the sample;
(C) Date and time sampling started and ended Sampler's
name(s) and title(s) and the names of others onsite;
(D) Grower's or processor's name, address, and license number
Date and time sampling started and ended;
(E) Batch number of the batch from which the sample was obtained
Grower's or processor's name, address, and license number;
(F) Sample matrix Batch number of the batch from which the
sample was obtained;
(G) Total batch size, by weight or unit count Total weight or
unit count;
(H) Total weight or unit count of the primary sample Total batch
size, by weight or unit count;
(I) Total weight or unit count of the reserve sample Total
weight or unit count of the primary sample;
(J) The unique sample identification number for each sample
Total weight or unit count of the reserve sample;
(K) Name, business address, and license number of the person
who transports the samples to the laboratory The unique sample
identification number for each sample;
(L) Requested analyses Name, business address, and license
2021.06_OSDH681_OMMARulesChapterAsAmended
83
number of the person who transports the samples to the
laboratory;
(M) Sampling conditions, including temperature Requested
analyses;
(N) Problems encountered and corrective actions taken during the
sampling process, if any; and Sampling conditions, including
temperature;
(O) Any other observations from sampling, including major
inconsistencies in the medical marijuana color, size, or smell.
Problems encountered and corrective actions taken during the
sampling process, if any; and
(P) Any other observations from sampling, including major
inconsistencies in the medical marijuana color, size, or smell.
(10) The laboratory shall maintain inventory manifest documentation
listed in OAC 310:681-3-6 and utilize an electronic inventory
management system that meets the requirements set forth in OAC
310:681-5-6(d) for each sample that the laboratory collects,
transports, and analyzes.
(11) A laboratory must maintain the documentation required in these
rules for at least two (2) years and must provide that information
to the Department upon request Commercial licensees shall document
all employee training on a testing laboratory's standard operating
procedures.
(12) Commercial licensees must maintain the documentation required
in these rules for at least two (2) years and must provide that
information to the Department upon request.
(b) Sample size.
(1) To obtain a representative sample of a harvest batch, a total of
0.5% of the batch is collected from different areas of the batch
following the laboratory's approved protocol. The sample is then
homogenized and aliquoted into a primary sample and reserve sample,
which shall be equal in amounts. The primary sample and reserve
sample shall be in the amounts specified in the laboratory's
standard operating procedure. Any amounts left over after aliquoting
may be returned to the harvest batch.
(2) To obtain a representative sample of a processed batch that is
well mixed or homogeneous by its nature, obtain an amount sufficient
to be aliquoted into a primary sample and a reserve sample, which
shall be equal in amounts. If the batch is of not homogeneous or is
of unknown homogeneity, then 0.5% of the batch shall be collected
from different portions of the batch following the laboratory's
approved protocol. The sample is then homogenized and aliquoted
into a primary sample and reserve sample, which shall be equal in
amounts. The primary sample and reserve sample shall be in the
amounts specified in the laboratory's standard operating procedure.
Any amounts left over after aliquoting may be returned to the
harvest batch.
(c) Sampling standard operating procedures.
(1) Samples collected must be representative of the entire batch to
ensure accurate microbiological analysis and foreign material
assessments.
(2) Sample protocol shall be approved by the laboratory director.
The laboratory shall develop and implement written sampling policies
2021.06_OSDH681_OMMARulesChapterAsAmended
84
and procedures that are appropriate for each test method and each
type of matrix to be tested and that are consistent with these
regulations. Sampling procedures must describe the laboratory's
method for collection, preparation, packaging, labeling,
documentation, and transport of samples from each matrix type the
laboratory tests.
(3) The sampling standard operating procedures (SOP) shall include
at least the following information:
(A) A step-by-step guide for obtaining samples from each matrix
type the laboratory samples;
(B) Protocols for ensuring that contaminants are not introduced
during sampling, including protocols relating to the sanitizing
of equipment and tools, protective garb, and sampling containers;
(C) Accepted test sample types;
(D) Minimum test sample size;
(E) Recommended test sample containers;
(F) Test sample labeling;
(G) Transport and storage conditions, such as refrigeration, as
appropriate to protect the physical and chemical integrity of the
sample;
(H) Other requirements, such as use of preservatives, inert gas,
or other measures designed to protect sample integrity; and
(I) Chain-of-custody documentation for each sample in accordance
with OAC 310:681-5-6.
(4) The sampling SOP shall be signed and dated by the medical
laboratory director and shall include any revision dates and
authors. The laboratory director's signature denotes approval of
the plan.
(5) The laboratory shall retain a controlled copy of the sampling
SOP on the laboratory premises and ensure that the sampling SOP is
accessible to the sampler in the field during sampling.
(d) Sample handling, storage and disposal. A laboratory shall
establish sample handling procedures for the tracking of test samples
through the analytical process (by weight, volume, number, or other
appropriate measure) to prevent diversion.
(1) The laboratory shall store each test sample under the
appropriate conditions appropriate to protect the physical and
chemical integrity of the sample.
(2) Analyzed test samples consisting of medical marijuana or medical
marijuana products shall be held in a controlled access area pending
destruction or other disposal.
(3) Any portion of a medical marijuana product test sample that is
not destroyed during analysis shall be: Reserve samples shall be
maintained and properly stored by the laboratory for at least thirty
(30) days.
(4) After the required thirty (30) day storage period, any portion
of a medical marijuana or medical marijuana product test sample
that is not destroyed during analysis shall be:
(A) Returned to the licensed individual or entity that provided
the sample after the required retention period for reserve
samples;
(B) Transported to a state or local law enforcement office; or
(C) Disposed of in accordance with OAC 310:681-5-10 (relating to
2021.06_OSDH681_OMMARulesChapterAsAmended
85
medical marijuana waste disposal).
(e) Data reporting.
(1) The laboratory shall generate a certificate of analysis (COA)
for each primary sample that the laboratory analyzes.
(2) The laboratory shall issue the COA to the requester within
two (2) business days after technical and administrative review
of analysis has been completed. A laboratory shall not withhold a
COA reporting a failed test from the requester for any reason.
(3) The COA All COAs, whether in paper or electronic form, shall
contain, at minimum, the following information:
(A) The name, address, license number, and contact information of
the laboratory that conducted the analysis;
(B) If the laboratory sends a sample to another laboratory for
testing, the reference laboratory must be identified as
having performed that test;
(C) The name, address, and license number of the requester;
(D) The description of the type or form of the test sample (leaf,
flower, powder, oil, specific edible product, etc.) and its
total primary sample weight in grams, reported to the nearest
gram;
(E) The unique sample identifier;
(F) Batch number of the batch from which the sample was obtained;
(G) Sample history, including the date collected, the date
received by the laboratory, and the date(s) of sample
analyses and corresponding testing results, including units
of measure where applicable;
(H) The analytical methods used, including at a minimum
identification of the type of analytical equipment used
(e.g., GC, HPLC, UV, etc.);
(I) The reporting limit for each analyte tested;
(J) Any compounds detected during the analyses of the sample that
are not among the targeted analytes and are unknown,
unidentified, tentatively identified or known and injurious to
human health if consumed, if any;
(K) The identity of the supervisory or management personnel who
reviewed and verified the data and results and ensured that
data quality, calibration, and other applicable requirements
were met.; and
(L) Definitions of any abbreviated terms.
(4) The laboratory shall report test results for each primary sample
on the COA as follows:
(A) When reporting quantitative results for each analyte, the
laboratory shall use the appropriate units of measurement as
required under this chapter and indicate "pass" or "fail";
(B) When reporting qualitative results for each analyte, the
laboratory shall indicate "pass" or "fail";
(C) When reporting results for any analytes that were detected
below the analytical method limit of quantitation (LOQ),
indicate "Pass" and "Fail" must be clear, conspicuous, and
easily identifiable in a font size no less than the size of 12
pt font in Times New Roman and shall not be in fine print or
footnotes;
(D) Indicate "NT" for not tested for any test that the
2021.06_OSDH681_OMMARulesChapterAsAmended
86
laboratory did not perform. When reporting results for any
analytes that were detected below the analytical method limit of
quantitation (LOQ), indicate "<LOQ" and list the results for
analytes that were detected above the LOQ but below the
allowable limit; and
(E) Indicate "NT" for not tested for any test that the
laboratory did not perform.
(5) Upon detection of any compounds during the analyses of the
sample that are not among the targeted analytes and are unknown,
unidentified, tentatively identified, or known and injurious to
human health if consumed, laboratories shall notify the Department
immediately and shall submit to the Department a copy of the COA
containing those compounds as required in OAC 310:681-8-
3(e)(3)(I). The Department may require a processor or grower to
submit samples for additional testing, including testing for
analytes that are not required by these Rules, at the licensee's
expense.
(6) When a laboratory determines that a harvest batch or
production batch has failed any required testing, the laboratory
shall immediately notify the Department in the manner and form
prescribed by the Department on its website and shall submit a
copy of the COA to the Department within two (2) business days.
Submission of this information to the Department through the seed-
to-sale tracking system established by the Department or a seed-
to-sale tracking system that integrates with the Department-
established system shall be sufficient to satisfy this reporting
requirement.