510-RICR-00-00-9
510-RICR-00-00-9. RISBC-9 Enforcement and Implementation Procedure (version Amendment, 08/01/2007 to 08/01/2007)
RHODE ISLAND
STATE BUILDING CODE
SBC-9 Enforcement and Implementation Procedure
for Projects Under the Jurisdiction of the State of
Rhode Island
Effective August 1, 2007
Replaces Regulation SBC-9-98
Dated April 1, 1998
STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS
Department of Administration
BUILDING CODE STANDARDS COMMITTEE
One Capitol Hill
Providence, Rhode Island 02908-5859
(401) 222-3032
FAX NO. (401) 222-2599
RISBC-9
STATEMENT OF NEED
Pursuant to the State Building Code Chapter 23, Title 27.3, the Building Code
Standards Committee has promulgated Regulation SBC-9, as amended, dated August 1,
2007. In accordance with section 23-27.3-109.1 paragraphs 1-4 of the Code, the
Committee has the authority to adopt appropriate rules and regulations when necessary
to maintain the State Building Code current with national model codes and standards.
RISBC-9
STATE OF RHODE ISLAND
BUILDING CODE STANDARDS COMMITTEE
CHAIRMAN
VICE CHAIRMAN
Dana Newbrook, RA
Stephen C. Turner, PE
Architect
Public Member
EXECUTIVE COMMITTEE
Allan Durand
Builders Trades Council
Robert M. Stillings
Architect
Bruce Davey, PE
Structural Engineer
Russell Brown
John Pagliaro
Building Official
Building Official
James R. Carlson, RA
David F. Palmisciano
Public Member
Building Trades Council
G. Thomas Chabot
Gordon W. Preiss, PE
Electrical Contractor
Mechanical Engineer
Randy Collins, Jr., RLA
Marie Stoeckel
Landscape Architect
Public Health Official
Robert E. DeBlois, Jr.
Builder
Builder
Vacant
Paul DePace, PE
Building Official
Representative for the Disabled
Vacant
Donald Gagnon
Electrical Inspector
Minimum Housing Inspector
Vacant
John D. Gaskell, PE
Representative for the Disabled
Electrical Engineer
Vacant
Leonard P. Gemma
John P. Leyden, CBO
Master Plumber
State Building Commissioner
Executive Secretary
William Howe
Fire Official
Legal Counsel
RISBC-9
ENFORCEMENT AND IMPLEMENTATION PROCEDURES FOR PROJECTS
UNDER THE JURISDICTION
OF THE STATE OF RHODE ISLAND
REGULATION SBC-9
AUGUST 1, 2007
SECTION 1 ADMINISTRATION
1.1 TITLE
As authorized by Chapter 23-27.3 of the General Laws of Rhode Island, 1956 as
amended, and in accordance with Sections 23-27.3-108.2 and 23-27.3-109.1 of the State
Building Code, the Building Code Standards Committee has promulgated the following
rules and regulations for enforcement and implementation of this Code by the State
Building Commissioner as to any structures or buildings or parts thereof that are owned
or are temporarily or permanently under the jurisdiction of the State of Rhode Island or
any of its departments, commissions, agencies or authorities and as to any structures or
buildings or parts thereof that are built upon any land owned by, or under the
jurisdiction of the State of Rhode Island or any of its departments commissions,
agencies or authorities.
All other existing provisions shall remain in effect; amend section 1, 2, and 3 as
follows:
1.2 ENFORCEMENT
The provisions of Title 23, Chapter 27.3, Article 1, Administration and Enforcement,
shall apply to all projects under the jurisdiction of the State Building Commissioner.
1.3 DESIGN AND CONSTRUCTION PROCEDURES
The following provisions of section 23-27.3-128.0 shall be enforced for design and
construction control for projects under the jurisdiction of the Commission.
SBC9-1
RISBC-9
23-27.3-128.0 Design and Construction Procedures
23-27.3-128.1 Scope: The provisions of this section shall define the responsibility
required of the owner, architect, engineer, contractor and Building Official during the
design, construction and testing process for new or renovated buildings or structures.
128.1.1. Owners Responsibilities:
1. The owner shall be responsible for providing the services as required in section
23-27.3-128.3(1)(3).
2. When the owner retains, or is required by the building official to retain the
services of an architect or an engineer who shall provide the services as required
in Sections 23-27.3-128.2.2.
3. The building official shall require the owner to certify to the requirements of
items 1 or 2 prior to the issuance of a permit to the owner or his agent.
Architect/Engineer Responsibilities:
23-27.3-128.2.1 Drawings and Specifications: All drawings, specifications and
computations for new construction, alteration, repair, or expansion work involving the
practice of professional engineering or architecture as defined by Rhode Island State
Law, shall be prepared by professional engineers or registered architects as licensed or
registered by the State of Rhode Island. All said drawings, computations and
specifications required for a building permit application for such work must be prepared
by or under the direct supervision of a professional engineer or registered architect and
bear his signature and seal in accordance with the Rhode Island statutes and regulations
governing the professional licensing or registration of engineers or architects and shall
signify to the best of his knowledge that the drawings, computations and specifications
shall meet the applicable provisions of this code and acceptable engineering practices
and all applicable laws and ordinances.
SBC9-2
RISBC-9
23-27.3-128.2.2 Responsibilities: A professional engineer or registered architect on
behalf of the owner shall be responsible for the following:
1. Review of the shop drawings, samples and other submittals of the contractor as
required by the construction contract documents submitted for permit and approval
for conformance to the design concept.
2. All change orders to the contract documents shall be submitted to the Building
Official after approval by the professional engineer or registered architect.
3. Review and approval of the testing procedures listed in Section 23-27.3-128.4
and referenced standards within each code. The engineer or architect shall notify
the owner, building official and contractor of any deviations and the required
corrective measures taken.
4. Insure special engineering or architectural inspection of critical construction
components requiring controlled materials or construction specified in the accepted
engineering practice standards as listed in referenced standards within each code.
5. The professional engineer or registered architect or his representative shall
provide the necessary professional services and be present on the construction site
on a regular and periodic basis to determine that, generally, the work is proceeding
in accordance with the documents approved for the permit.
23-27.3-128.2.3 Reporting: The professional engineer or registered architect shall
submit periodically in a form at regular construction inspection intervals acceptable to
the building official, a progress report together with pertinent comments. At the
completion of construction, the engineer or architect shall submit to the building official
a report as to the satisfactory completion and the readiness of the project for occupancy
(accepting any items not endangering such occupancy or operation and listing pertinent
deviations from the approved permit documents).
23-27.3-128.3 Construction Contractor Responsibilities: The actual construction of the
work shall be the responsibility of the owner or the contractor designated as his agent
and who shall:
SBC9-3
RISBC-9
1. Perform all work in accordance with the construction documents on file with the
building official.
2. Perform all work in a safe and satisfactory manner in accordance with all
applicable local, state and federal statutes and regulations.
3. Upon completion of the construction shall certify to the best of his knowledge
and belief that such work has been done in substantial accord with items 1 and 2
above and with all pertinent deviations.
128.4 Testing Required: The referenced standards listed in the appendices or the test
of this Code contain many field or agency tests which are required for the proper
installation or erection of any buildings or structure and its component structural,
electrical, mechanical, plumbing assemblies. It shall be the responsibility of the
engineer or architect to specify the tests as required by this code and its standards; the
owner contractor shall then secure the services of a laboratory to perform said test. The
engineer or the architect shall file the periodic test reports and report any deviations or
any corrective measures to be taken as required 23-27.3-128.2.2(3).
Examples of Testing Required – among others:
1. Soil testing for loading conditions and water levels.
2. Concrete testing for strength i.e. slump test, cylinders, core tests, etc.
3. Structural steel testing for welds, bolts and rivets in accordance with industry
standards.
23-27.3-128.5 Building Officials Responsibilities: The building official shall be
responsible for carrying out the duties and responsibilities as outlined in Article I of this
Code with regard to the issuing of permits, the maintenance of records, the performance
of inspections and any other administrative procedures except as may be specifically
exempt herein. Nothing contained in this section shall have the effect of waiving or
limiting the building official’s authority to enforce this Code with respect to
examination of the contract documents, including the plans, computations and
specifications, and related field inspections.
SBC9-4
RISBC-9
23-27.3-128.5.1
Waiver of Plan Examination: The examination of plans may be
waived when the plans for the erection or alteration of a building are prepared by a
professional engineer or architect and said professional engineer or architect has stated
in writing that he has supervised the preparation of the architectural, structural,
electrical, plumbing and mechanical design contract documents and that he will review
and approve all working drawings for said construction and that said document shall
conform to all provisions of this Code and all rules and regulations adopted under its
provisions.
23-27.3-128.5.2 Waiver of Detailed Field Inspection: The building official may
waive the detailed department field inspection when the professional engineer or
architect certifies that the construction work will be built under his field observations
and in accordance with the approved contract documents, and that he will certify to the
best of his knowledge, information and belief that the construction is in substantial,
accordance with said documents and that he will submit a report in compliance with
Section 23-27.3-128.2.3.
23-27.3-128.5.3: The building official may utilize this inspection waiver, in whole or in
part, but he must cause sufficient plan review and construction inspection by the
building official or staff to insure that:
1. The proposed usage and facilities are in conformance with the zoning
ordinances and this Code:
2. The contractor is maintaining the required construction safety; and
3. The professional engineer or registered architect is, in fact, providing the
necessary inspections; and
4. State approvals for septic systems, wetlands, and fire safety code provisions
have been submitted prior to the issuance of a permit by the building official.
23-27.3-128.5.4 Building Permit Issuance or Requirements:
This special professional service requirement shall be determined prior to the issuance
of any permits and shall be a prerequisite for the permit issuance. Refusal by the owner
to provide such service as required by the building official shall result in the denial of
their permit. However, the owner may file an appeal as provided in Section 23-27.3-
127.1.
SBC9-5
RISBC-9
23-27.3-128.6
Special Technical Services: When application for unusual designs or
magnitude of construction are filed, the building official may refer such plans and
specifications to the State Building
Commissioner, or he may in his discretion, retain a professional engineer or architect,
for advice and recommendations as to said plans and specifications, safety design and
compliance with this Code. The building official may also employ a professional
engineer or architect to observe the construction in the field to insure compliance with
approved plans and permit. Upon completion of the work the architect or engineer
employed, shall file with the building official a report to the effect that to the best of his
knowledge and belief, the building has been erected in accordance with accepted
engineering practice and in conformity to all the statutory provisions governing building
construction for the designated use group classification of the building structure, in
respect to use, fire grading, floor and occupancy loads. All fees and costs related to the
performance of special technical services shall be borne by the owner.
23-27.3-128.7 Fees and Costs: All fees and costs related to performance of special
professional services shall be borne by the owner.
SECTION 2 APPEALS
2.1 GENERAL
Anyone aggrieved by a decision of the Commissioner may appeal to the State Board of
Appeals in accordance with the provisions of section 23-27.3-127.1 of the State
Building Code. No fee shall be charged to any state agency, department, commission or
authority for an appeal.
SBC9-6
RISBC-9
SECTION 3.0 FEES STATE BUILDING PERMITS
NEW BUILDINGS, ADDITIONS, ALTERATIONS, STRUCTURES, ETC.
STATE PERMIT
FEE SCHEDULE
VALUATION
FEE FACTOR
FEE
.
From $0 to $3,000
---
$30.00 Flat Fee
*From $3,001 to $10,000
.01*
$30.00 minimum to
$100.00 maximum
From $10,001 to $20,000
---
$100.00 Flat Fee
*From $20,001 to No Limit
.005*
$100.00 minimum to
no maximum
* In these two ranges of valuations, multiply the valuation (cost of construction) times (x) the
fee factor to determine the fee.
All fees shall be paid by check, money order or state transfer forms (BFT). Cash is acceptable
only for fees less than $100.00.
Multiple permit applications can be paid for on one check, but insert the individual fees on each
permit application.
Occasionally, subcontractor fees (E, M, P) have been prepaid by the General Contractor. Check
the permit log or see Commissioner if there are any questions. Do not refuse the application.
Mechanical, Electrical, Plumbing and Roofing permit applications must be accompanied by a
copy of the contractor’s license (front and back). General Contractors are not required to be
licensed at this time.
SBC9-7
RISBC-9
PLAN REVIEW FEES
The Following shall be charged for performing plan reviews in order to determine code
compliance on behalf of local municipalities. Applications for plan reviews shall be
accompanied by a letter of authorization from the local building official and the required plan
review fee.
BUILDING VALUATION*
FEE
$0-$500,000.00
(.0020)(.20%) of building
valuation but not less than
$100.00
Over $500,000.00
$1,000.00 plus .001 (.10%) of
building valuation over $500,000.00
(not charged to State Agencies)
*Based upon latest available ICC Building Valuation Data Document
HEARING FEES
State Board of Standards and Appeals Hearing
Application Fee (not charged to state agencies)…$100.00
a.
Stenographic costs for hearing held on behalf of municipalities without
appeal boards shall be paid by each municipality.
b.
Stenographic costs for hearings held as an appeal to municipal or state
action shall be paid by the appellant.
DEMOLITION OR MOVING
(No revision of wrecking permits allowed)
Each residential building, accessory building or structure of use
Group R3 or R4……………………………………………………$50.00
All other buildings or structures…………………………………...$100.00
SPECIAL ENGINEERING FEES
Special engineering fees shall be a multiple of direct personnel costs as negotiated by
the Commissioner on each program or project requiring said services.
SBC9-8
RISBC-9
CODE BOOKS:
State Code Book Prices
All prices include RI Sales Tax
Additional Fee
Mail Ordering
SBC-1-2004
International Building Code 2006 Edition
**
---
RI Amendments
$10.00 $2.50
SBC-2 -2004
Rhode Island One & Two Family Code
International Residential Code 2006 Edition
**
---
RI Amendments
$10.00 $2.50
SBC-3-2004
State Plumbing Code
International Plumbing Code 2006 Edition
**
---
RI Amendments
$5.00 $2.50
SBC-4-2004
State Mechanical Code
International Mechanical Code 2006 Edition
**
---
RI Amendments
$5.00 $2.50
SBC-5
National Electrical Code 2005 Edition (incl. Amendments)
$60.00*** ---
RI Amendments (effective 2006)
$3.00 $1.00
SBC-6
Reserved
---
SBC-7
Reserved
---
SBC-8-2004
State Energy Code
International Energy Conservation Code 2006 Edition
**
RI Amendments
$5.00 $1.00
SBC-9
Enforcement and Procedures Under Jurisdiction of RI (2007) $0.00 $0.00
SBC-10 Code Interpretation (1998)
$0.00 $0.00
SBC-11 Certification of Local Officials and Inspectors
(Effective 1/1/03)
$0.00 $0.00
SBC-12 New Materials and Methods of Construction
$0.00 $0.00
(1998 Edition)
SBC-13 Building Code Provisions for Existing Schools (1997)
$0.00 $10.00
SBC-14 Reserved
---
SBC-15 Reserved
---
SBC9-9
RISBC-9
Additional Fee
Mail Ordering
SBC-16 Reserved
---
SBC-17 Public Buildings Accessible (1998)
$0.00 $0.00
SBC-18 Native Lumber (1998)
$0.00 $0.00
SBC-19-2004
State Fuel Gas Code
International Fuel Gas Code 2006 Edition
**
RI Amendments (2007 Edition)
$5.00 $2.50
SRC-1
State Rehabilitation Code
$16.00 $5.00
All of above RI Amendments as PDF
$25.00
(Effective 5/1/02)
** The referenced code books are available through the following suggested vendors:
(SBC-1) International Building Code 2006
International Code Council
(SBC-2) International Residential Code 2006
4051 West Flossmoor Road
(SBC-3) International Plumbing Code 2006
Country Club Hills, IL 60478-57945
(SBC-4) International Mechanical Code 2006
1-800-323-1103
(SBC-8) International Energy Conservation Code 2006
(SBC-19) International Fuel Gas Code 2006
(SBC-5) National Electrical Code 2005 Edition
The National Electrical Code 2005 Edition is also
NFPA
available from:
1 Batterymarch Park
PO Box 9101
Quincy, MA 02269-9101
1-800-562-1197
ANSI A117.1-03 is also available from:
ANSI
11 West 42nd Street
New York, NY 10036
Call the respective organization for pricing and availability. Local sources may be available for direct
pickup. Call this office (222-3033) for further details.
**
See above for ordering
***
Currently in-stock – Call for availability
Website for amendments: www.rules.state.ri.us/rules/
SBC9-10
RISBC-9
STATE BUILDING CODE REGULATIONS – 2006
The following list includes all regulations promulgated by the State Building Code Standards Committee.
All regulations are available for a fee at the State Building Commission.
1.
Building Code…………………………………………SBC-1-2007
2.
One and Two Dwelling Family
Dwelling Code………………………………………...SBC-2-2007
3.
Plumbing Code………………………………………..SBC-3-2007
4.
Mechanical Code……………………………………...SBC-4-2007
5.
Electrical Code………………………………………..SBC-5-2005
6.
Reserved…………………………………………...….SBC-6-2007
7.
Reserved…………..…………………………………..SBC-7
8.
State Energy Code…………………………………….SBC-8-2007
9.
Enforcement and Implementation
Procedures for Projects Under
the Jurisdiction of the State
of Rhode Island……………………………………….SBC-9-2007
10.
Code Interpretations…………………………………..SBC-10
11.
Certification of Building Officials,
Building, Electrical, Plumbing and
Mechanical Inspectors………………………………..SBC-11
12.
New Materials and Methods
of Construction……………………………………….SBC-12
13.
State Building Code
For Existing Schools………………………………….SBC-13
14.
Reserved
15.
Reserved
16.
Reserved
17.
Public Buildings Accessibility
Meeting Standards…………………………………….SBC-17
18.
Native Lumber………………………………………...SBC-18
19.
Fuel Gas Code…………………………………………SBC-19-2007
SBC9-11
RISBC-9