WAC 51-11C-403329. Tables C403.3.2(9) through C403.3.2(16) — HVAC equipment minimum efficiency requirements

Last amended: 2024Year: 2026Length: 4,939 wordsOfficial source
Table C403.3.2(9) Electrically Operated Variable Refrigerant Flow Air-to-Air and Applied Heat Pumps — Minimum Efficiency Requirements b Equipment Type Size Category Heating Section Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a < 65,000 Btu/h All VRF Multi-Split System 13.0 SEER ≥ 65,000 Btu/h and < 135,000 Btu/h Electric Resistance (or none) VRF Multi-Split System 11.0 EER 14.6 IEER ≥ 65,000 Btu/h and < 135,000 Btu/h Electric Resistance (or none) VRF Multi-Split System with Heat Recovery 10.8 EER 14.4 IEER VRF Air Cooled (cooling mode) ≥ 135,000 Btu/h and < 240,000 Btu/h Electric Resistance (or none) VRF Multi-Split System 10.6 EER 13.9 IEER AHRI 1230 ≥ 135,000 Btu/h and < 240,000 Btu/h Electric Resistance (or none) VRF Multi-Split System with Heat Recovery 10.4 EER 13.7 IEER ≥ 240,000 Btu/h Electric Resistance (or none) VRF Multi-Split System 9.5 EER 12.7 IEER ≥ 240,000 Btu/h Electric Resistance (or none) VRF Multi-Split System with Heat Recovery 9.3 EER 12.5 IEER < 65,000 Btu/h All VRF Multi-Split System 86ºF entering water 12.0 EER 16.0 IEER < 65,000 Btu/h All VRF Multi-Split System with Heat Recovery 86ºF entering water 11.8 EER 15.8 IEER ≥ 65,000 Btu/h and < 135,000 Btu/h All VRF Multi-Split System 86ºF entering water 12.0 EER 16.0 IEER VRF Water Source (cooling mode) ≥ 65,000 Btu/h and < 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 86ºF entering water 11.8 EER 15.8 IEER AHRI 1230 ≥ 135,000 Btu/h and < 240,000 Btu/h All VRF Multi-Split System 86ºF entering water 10.0 EER 14.0 IEER ≥ 135,000 Btu/h and < 240,000 Btu/h All VRF Multi-Split System with Heat Recovery 86ºF entering water 9.8 EER 13.8 IEER ≥ 240,000 Btu/h All VRF Multi-Split System 86ºF entering water 10.0 EER 12.0 IEER ≥ 240,000 Btu/h All VRF Multi-Split System with Heat Recovery 86ºF entering water 9.8 EER 11.8 IEER < 135,000 Btu/h All VRF Multi-Split System 59ºF entering water 16.2 EER < 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 59ºF entering water 16.0 EER VRF Groundwater Source (cooling mode) ≥ 135,000 Btu/h All VRF Multi-Split System 59ºF entering water 13.8 EER AHRI 1230 ≥ 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 59ºF entering water 13.6 EER < 135,000 Btu/h All VRF Multi-Split System 77ºF entering water 13.4 EER VRF Ground Source (cooling mode) < 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 77ºF entering water 13.2 EER AHRI 1230 ≥ 135,000 Btu/h All VRF Multi-Split System 77ºF entering water 11.0 EER ≥ 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 77ºF entering water 10.8 EER < 65,000 Btu/h (cooling capacity) VRF Multi-Split System 7.7 HSPF VRF Air Cooled (heating mode) ≥ 65,000 Btu/h and < 135,000 Btu/h (cooling capacity) VRF Multi-Split System 47ºF db/43ºF wb outdoor air 17ºF db/15ºF wb outdoor air 3.3 COP 2.25 COP AHRI 1230 ≥ 135,000 Btu/h (cooling capacity) VRF Multi-Split System 47ºF db/43ºF wb outdoor air 17ºF db/15ºF wb outdoor air 3.2 COP 2.05 COP < 65,000 Btu/h (cooling capacity) VRF Multi-Split System 68ºF entering water 4.3 COP ≥ 65,000 Btu/h and < 135,000 Btu/h (cooling capacity) VRF Multi-Split System 68ºF entering water 4.3 COP VRF Water Source (heating mode) ≥ 135,000 Btu/h and < 240,000 Btu/h (cooling capacity) VRF Multi-Split System 68ºF entering water 4.0 COP AHRI 1230 ≥ 240,000 Btu/h (cooling capacity) VRF Multi-Split System 68ºF entering water 3.9 COP VRF Groundwater Source < 135,000 Btu/h (cooling capacity) VRF Multi-Split System 50ºF entering water 3.6 COP AHRI 1230 (heating mode) ≥ 135,000 Btu/h (cooling capacity) VRF Multi-Split System 50ºF entering water 3.3 COP VRF Ground Source < 135,000 Btu/h (cooling capacity) VRF Multi-Split System 32ºF entering water 3.1 COP AHRI 1230 (heating mode) ≥ 135,000 Btu/h (cooling capacity) VRF Multi-Split System 32ºF entering water 2.8 COP Equipment Type Size Category Heating Section Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a < 65,000 Btu/h All VRF Multi-Split System 13.0 SEER ≥ 65,000 Btu/h and < 135,000 Btu/h Electric Resistance (or none) VRF Multi-Split System 11.0 EER 14.6 IEER ≥ 65,000 Btu/h and < 135,000 Btu/h Electric Resistance (or none) VRF Multi-Split System with Heat Recovery 10.8 EER 14.4 IEER VRF Air Cooled (cooling mode) ≥ 135,000 Btu/h and < 240,000 Btu/h Electric Resistance (or none) VRF Multi-Split System 10.6 EER 13.9 IEER AHRI 1230 ≥ 135,000 Btu/h and < 240,000 Btu/h Electric Resistance (or none) VRF Multi-Split System with Heat Recovery 10.4 EER 13.7 IEER ≥ 240,000 Btu/h Electric Resistance (or none) VRF Multi-Split System 9.5 EER 12.7 IEER ≥ 240,000 Btu/h Electric Resistance (or none) VRF Multi-Split System with Heat Recovery 9.3 EER 12.5 IEER < 65,000 Btu/h All VRF Multi-Split System 86ºF entering water 12.0 EER 16.0 IEER < 65,000 Btu/h All VRF Multi-Split System with Heat Recovery 86ºF entering water 11.8 EER 15.8 IEER ≥ 65,000 Btu/h and < 135,000 Btu/h All VRF Multi-Split System 86ºF entering water 12.0 EER 16.0 IEER VRF Water Source (cooling mode) ≥ 65,000 Btu/h and < 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 86ºF entering water 11.8 EER 15.8 IEER AHRI 1230 ≥ 135,000 Btu/h and < 240,000 Btu/h All VRF Multi-Split System 86ºF entering water 10.0 EER 14.0 IEER ≥ 135,000 Btu/h and < 240,000 Btu/h All VRF Multi-Split System with Heat Recovery 86ºF entering water 9.8 EER 13.8 IEER ≥ 240,000 Btu/h All VRF Multi-Split System 86ºF entering water 10.0 EER 12.0 IEER ≥ 240,000 Btu/h All VRF Multi-Split System with Heat Recovery 86ºF entering water 9.8 EER 11.8 IEER < 135,000 Btu/h All VRF Multi-Split System 59ºF entering water 16.2 EER < 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 59ºF entering water 16.0 EER VRF Groundwater Source (cooling mode) ≥ 135,000 Btu/h All VRF Multi-Split System 59ºF entering water 13.8 EER AHRI 1230 ≥ 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 59ºF entering water 13.6 EER < 135,000 Btu/h All VRF Multi-Split System 77ºF entering water 13.4 EER VRF Ground Source (cooling mode) < 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 77ºF entering water 13.2 EER AHRI 1230 ≥ 135,000 Btu/h All VRF Multi-Split System 77ºF entering water 11.0 EER ≥ 135,000 Btu/h All VRF Multi-Split System with Heat Recovery 77ºF entering water 10.8 EER < 65,000 Btu/h (cooling capacity) VRF Multi-Split System 7.7 HSPF VRF Air Cooled (heating mode) ≥ 65,000 Btu/h and < 135,000 Btu/h (cooling capacity) VRF Multi-Split System 47ºF db/43ºF wb outdoor air 17ºF db/15ºF wb outdoor air 3.3 COP 2.25 COP AHRI 1230 ≥ 135,000 Btu/h (cooling capacity) VRF Multi-Split System 47ºF db/43ºF wb outdoor air 17ºF db/15ºF wb outdoor air 3.2 COP 2.05 COP < 65,000 Btu/h (cooling capacity) VRF Multi-Split System 68ºF entering water 4.3 COP ≥ 65,000 Btu/h and < 135,000 Btu/h (cooling capacity) VRF Multi-Split System 68ºF entering water 4.3 COP VRF Water Source (heating mode) ≥ 135,000 Btu/h and < 240,000 Btu/h (cooling capacity) VRF Multi-Split System 68ºF entering water 4.0 COP AHRI 1230 ≥ 240,000 Btu/h (cooling capacity) VRF Multi-Split System 68ºF entering water 3.9 COP VRF Groundwater Source < 135,000 Btu/h (cooling capacity) VRF Multi-Split System 50ºF entering water 3.6 COP AHRI 1230 (heating mode) ≥ 135,000 Btu/h (cooling capacity) VRF Multi-Split System 50ºF entering water 3.3 COP VRF Ground Source < 135,000 Btu/h (cooling capacity) VRF Multi-Split System 32ºF entering water 3.1 COP AHRI 1230 (heating mode) ≥ 135,000 Btu/h (cooling capacity) VRF Multi-Split System 32ºF entering water 2.8 COP For SI: °C = [(°F) - 32]/1.8, 1 British thermal unit per hour = 0.2931 W, db = dry bulb temperature, wb = wet bulb temperature. a Chapter 6 contains a complete specification of the referenced standards, which include test procedures, including the reference year version of the test procedure. b This table is a replica of ASHRAE 90.1 Table 6.8.1-9 Electrically Operated Variable-Refrigerant-Flow and Applied Heat Pumps — Minimum Efficiency Requirements. Table C403.3.2(10) Floor-Mounted Air Conditioners and Condensing Units Serving Computer Rooms—Minimum Efficiency Requirements b Equipment Type Standard Model Net Sensible Cooling Capacity Minimum Net Sensible COP Rating Conditions Return Air (dry bulb/dew point) Test Procedure a Air cooled Downflow < 80,000 Btu/h 2.70 85°F/52°F (Class 2) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.58 ≥ 295,000 Btu/h 2.36 Upflow - Ducted < 80,000 Btu/h 2.67 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.55 ≥ 295,000 Btu/h 2.33 Upflow - Nonducted ˃ 65,000 Btu/h 2.16 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 2.04 ≥ 240,000 Btu/h 1.89 Horizontal ˃ 65,000 Btu/h 2.65 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.55 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.47 Air cooled with fluid economizer Downflow < 80,000 Btu/h 2.70 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.58 ≥ 295,000 Btu/h 2.36 Upflow - Ducted < 80,000 Btu/h 2.67 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.55 ≥ 295,000 Btu/h 2.33 Upflow - Nonducted ˃ 65,000 Btu/h 2.09 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 1.99 ≥ 240,000 Btu/h 1.81 Horizontal ˃ 65,000 Btu/h 2.65 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.55 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.47 Water cooled Downflow < 80,000 Btu/h 2.82 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.73 ≥ 295,000 Btu/h 2.67 Upflow - Ducted < 80,000 Btu/h 2.79 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.70 ≥ 295,000 Btu/h 2.64 Upflow - Nonducted ˃ 65,000 Btu/h 2.43 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 2.32 ≥ 240,000 Btu/h 2.20 Horizontal ˃ 65,000 Btu/h 2.79 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.68 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.60 Water cooled with fluid economizer Downflow < 80,000 Btu/h 2.77 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.68 ≥ 295,000 Btu/h 2.61 Upflow - Ducted < 80,000 Btu/h 2.74 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.65 ≥ 295,000 Btu/h 2.58 Upflow - Nonducted ˃ 65,000 Btu/h 2.35 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 2.24 ≥ 240,000 Btu/h 2.12 Horizontal ˃ 65,000 Btu/h 2.71 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.60 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.54 Glycol cooled Downflow < 80,000 Btu/h 2.56 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.24 ≥ 295,000 Btu/h 2.21 Upflow - Ducted < 80,000 Btu/h 2.53 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.21 ≥ 295,000 Btu/h 2.18 Upflow - Nonducted ˃ 65,000 Btu/h 2.08 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 1.90 ≥ 240,000 Btu/h 1.81 Horizontal ˃ 65,000 Btu/h 2.48 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.18 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.18 Glycol cooled with fluid economizer Downflow < 80,000 Btu/h 2.51 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.19 ≥ 295,000 Btu/h 2.15 Upflow - Ducted < 80,000 Btu/h 2.48 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.16 ≥ 295,000 Btu/h 2.12 Upflow - Nonducted ˃ 65,000 Btu/h 2.00 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 1.82 ≥ 240,000 Btu/h 1.73 Horizontal ˃ 65,000 Btu/h 2.44 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.10 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.10 Equipment Type Standard Model Net Sensible Cooling Capacity Minimum Net Sensible COP Rating Conditions Return Air (dry bulb/dew point) Test Procedure a Air cooled Downflow < 80,000 Btu/h 2.70 85°F/52°F (Class 2) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.58 ≥ 295,000 Btu/h 2.36 Upflow - Ducted < 80,000 Btu/h 2.67 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.55 ≥ 295,000 Btu/h 2.33 Upflow - Nonducted ˃ 65,000 Btu/h 2.16 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 2.04 ≥ 240,000 Btu/h 1.89 Horizontal ˃ 65,000 Btu/h 2.65 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.55 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.47 Air cooled with fluid economizer Downflow < 80,000 Btu/h 2.70 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.58 ≥ 295,000 Btu/h 2.36 Upflow - Ducted < 80,000 Btu/h 2.67 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.55 ≥ 295,000 Btu/h 2.33 Upflow - Nonducted ˃ 65,000 Btu/h 2.09 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 1.99 ≥ 240,000 Btu/h 1.81 Horizontal ˃ 65,000 Btu/h 2.65 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.55 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.47 Water cooled Downflow < 80,000 Btu/h 2.82 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.73 ≥ 295,000 Btu/h 2.67 Upflow - Ducted < 80,000 Btu/h 2.79 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.70 ≥ 295,000 Btu/h 2.64 Upflow - Nonducted ˃ 65,000 Btu/h 2.43 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 2.32 ≥ 240,000 Btu/h 2.20 Horizontal ˃ 65,000 Btu/h 2.79 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.68 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.60 Water cooled with fluid economizer Downflow < 80,000 Btu/h 2.77 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.68 ≥ 295,000 Btu/h 2.61 Upflow - Ducted < 80,000 Btu/h 2.74 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.65 ≥ 295,000 Btu/h 2.58 Upflow - Nonducted ˃ 65,000 Btu/h 2.35 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 2.24 ≥ 240,000 Btu/h 2.12 Horizontal ˃ 65,000 Btu/h 2.71 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.60 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.54 Glycol cooled Downflow < 80,000 Btu/h 2.56 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.24 ≥ 295,000 Btu/h 2.21 Upflow - Ducted < 80,000 Btu/h 2.53 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.21 ≥ 295,000 Btu/h 2.18 Upflow - Nonducted ˃ 65,000 Btu/h 2.08 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 1.90 ≥ 240,000 Btu/h 1.81 Horizontal ˃ 65,000 Btu/h 2.48 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.18 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.18 Glycol cooled with fluid economizer Downflow < 80,000 Btu/h 2.51 85°F/52°F (Class 1) AHRI 1360 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.19 ≥ 295,000 Btu/h 2.15 Upflow - Ducted < 80,000 Btu/h 2.48 ≥ 80,000 Btu/h and < 295,000 Btu/h 2.16 ≥ 295,000 Btu/h 2.12 Upflow - Nonducted ˃ 65,000 Btu/h 2.00 75°F/52°F (Class 1) ≥ 65,000 Btu/h and < 240,000 Btu/h 1.82 ≥ 240,000 Btu/h 1.73 Horizontal ˃ 65,000 Btu/h 2.44 ≥ 65,000 Btu/h and < 240,000 Btu/h 2.10 95°F/52°F (Class 3) ≥ 240,000 Btu/h 2.10 For SI: 1 British thermal unit per hour = 0.2931 W, °C = [(°F) - 32]/1.8. a Chapter 6 contains a complete specification of the referenced standards, which include test procedures, including the reference year version of the test procedure. b This table is a replica of ASHRAE 90.1 Table 6.8.1-10 Floor-Mounted Air Conditioners and Condensing Units Serving Computer Rooms — Minimum Efficiency Requirements. Table C403.3.2(11) Vapor-Compression-Based Indoor Pool Dehumidifiers — Minimum Efficiency Requirements b Equipment Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a Single package indoor (with or without economizer) Rating Conditions: A or C 3.5 MRE AHRI 910 Single package indoor water cooled (with or without economizer) Rating Conditions: A, B or C 3.5 MRE Single package indoor air cooled (with or without economizer) Rating Conditions: A, B or C 3.5 MRE Split system indoor air cooled (with or without economizer) Rating Conditions: A, B or C 3.5 MRE Equipment Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a Single package indoor (with or without economizer) Rating Conditions: A or C 3.5 MRE AHRI 910 Single package indoor water cooled (with or without economizer) Rating Conditions: A, B or C 3.5 MRE Single package indoor air cooled (with or without economizer) Rating Conditions: A, B or C 3.5 MRE Split system indoor air cooled (with or without economizer) Rating Conditions: A, B or C 3.5 MRE a Chapter 6 contains a complete specification of the referenced standards, which include test procedures, including the reference year version of the test procedure. b This table is a replica of ASHRAE 90.1 Table 6.8.1-11 Vapor-Compressor-Based Indoor Pool Dehumidifiers — Minimum Efficiency Requirements. Table C403.3.2(12) Electrically Operated DX-DOAS Units, Single-Package and Remote Condenser, Without Energy Recovery — Minimum Efficiency Requirements b Equipment Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a Air cooled (dehumidification mode) 4.0 ISMRE AHRI 920 Air source heat pumps (dehumidification mode) 4.0 ISMRE AHRI 920 Water cooled (dehumidification mode) Cooling tower condenser water 4.9 ISMRE AHRI 920 Chilled water 6.0 ISMRE Air source heat pump (heating mode) 2.7 ISCOP AHRI 920 Water source heat pump (dehumidification mode) Ground source, closed loop 4.8 ISMRE AHRI 920 Ground-water source 5.0 ISMRE Water source 4.0 ISMRE Water source heat pump (heating mode) Ground source, closed loop 2.0 ISCOP AHRI 920 Ground-water source 3.2 ISCOP Water source 3.5 ISCOP Equipment Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a Air cooled (dehumidification mode) 4.0 ISMRE AHRI 920 Air source heat pumps (dehumidification mode) 4.0 ISMRE AHRI 920 Water cooled (dehumidification mode) Cooling tower condenser water 4.9 ISMRE AHRI 920 Chilled water 6.0 ISMRE Air source heat pump (heating mode) 2.7 ISCOP AHRI 920 Water source heat pump (dehumidification mode) Ground source, closed loop 4.8 ISMRE AHRI 920 Ground-water source 5.0 ISMRE Water source 4.0 ISMRE Water source heat pump (heating mode) Ground source, closed loop 2.0 ISCOP AHRI 920 Ground-water source 3.2 ISCOP Water source 3.5 ISCOP a Chapter 6 contains a complete specification of the referenced standards, which include test procedures, including the reference year version of the test procedure. b This table is a replica of ASHRAE 90.1 Table 6.8.1-13 Electrically Operated DX-DOAS Units, Single-Package and Remote Condenser, without Energy Recovery — Minimum Efficiency Requirements. Table C403.3.2(13) Electrically Operated DX-DOAS Units, Single-Package and Remote Condenser, with Energy Recovery — Minimum Efficiency Requirements b Equipment Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a Air cooled (dehumidification mode) 5.2 ISMRE AHRI 920 Air source heat pumps (dehumidification mode) 5.2 ISMRE AHRI 920 Water cooled (dehumidification mode) Cooling tower condenser water 5.3 ISMRE AHRI 920 Chilled water 6.6 ISMRE Air source heat pump (heating mode) 3.3 ISCOP AHRI 920 Water source heat pump (dehumidification mode) Ground source, closed loop 5.2 ISMRE AHRI 920 Ground-water source 5.8 ISMRE Water source 4.8 ISMRE Water source heat pump (heating mode) Ground source, closed loop 3.8 ISCOP AHRI 920 Ground-water source 4.0 ISCOP Water source 4.8 ISCOP Equipment Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a Air cooled (dehumidification mode) 5.2 ISMRE AHRI 920 Air source heat pumps (dehumidification mode) 5.2 ISMRE AHRI 920 Water cooled (dehumidification mode) Cooling tower condenser water 5.3 ISMRE AHRI 920 Chilled water 6.6 ISMRE Air source heat pump (heating mode) 3.3 ISCOP AHRI 920 Water source heat pump (dehumidification mode) Ground source, closed loop 5.2 ISMRE AHRI 920 Ground-water source 5.8 ISMRE Water source 4.8 ISMRE Water source heat pump (heating mode) Ground source, closed loop 3.8 ISCOP AHRI 920 Ground-water source 4.0 ISCOP Water source 4.8 ISCOP a Chapter 6 contains a complete specification of the referenced standards, which include test procedures, including the reference year version of the test procedure. b This table is a replica of ASHRAE 90.1 Table 6.8.1-14 Electrically Operated DX-DOAS Units, Single-Package and Remote Condenser, with Energy Recovery — Minimum Efficiency Requirements. Table C403.3.2(14) Electrically Water Source Heat Pumps — Minimum Efficiency Requirements c Equipment Type Size Category b Heating Section Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a < 17,000 Btu/h All 86°F entering water 12.2 EER Water to air, water loop (cooling mode) ≥ 17,000 Btu/h and < 65,000 Btu/h All 86°F entering water 13.0 EER ISO 13256-1 ≥ 65,000 Btu/h and < 135,000 Btu/h All 86°F entering water 13.0 EER Water to air, ground water (cooling mode) < 135,000 Btu/h All 59°F entering water 18.0 EER Brine to air, ground loop (cooling mode) < 135,000 Btu/h All 77°F entering water 14.1 EER Water to water, water loop (cooling mode) < 135,000 Btu/h All 86°F entering water 10.6 EER Water to water, ground water (cooling mode) < 135,000 Btu/h All 59°F entering water 16.3 EER ISO 13256-2 Brine to water, ground loop (cooling mode) < 135,000 Btu/h All 77°F entering fluid 12.1 EER Water to air, water loop (heating mode) < 135,000 Btu/h (cooling capacity) 68°F entering water 4.3 COP H Water to air, ground water (heating mode) < 135,000 Btu/h (cooling capacity) 50°F entering water 3.7 COP H ISO 13256-1 Brine to air, ground loop (heating mode) < 135,000 Btu/h (cooling capacity) 32°F entering fluid 3.2 COP H Water to water, water loop (heating mode) < 135,000 Btu/h (cooling capacity) 68°F entering water 3.7 COP H ISO 13256-1 Water to water, ground water (heating mode) < 135,000 Btu/h (cooling capacity) 50°F entering water 3.1 COP H ISO 13256-2 Brine to water, ground loop (heating mode) < 135,000 Btu/h (cooling capacity) 32°F entering fluid 2.5 COP H ISO 13256-2 Equipment Type Size Category b Heating Section Type Subcategory or Rating Condition Minimum Efficiency Test Procedure a < 17,000 Btu/h All 86°F entering water 12.2 EER Water to air, water loop (cooling mode) ≥ 17,000 Btu/h and < 65,000 Btu/h All 86°F entering water 13.0 EER ISO 13256-1 ≥ 65,000 Btu/h and < 135,000 Btu/h All 86°F entering water 13.0 EER Water to air, ground water (cooling mode) < 135,000 Btu/h All 59°F entering water 18.0 EER Brine to air, ground loop (cooling mode) < 135,000 Btu/h All 77°F entering water 14.1 EER Water to water, water loop (cooling mode) < 135,000 Btu/h All 86°F entering water 10.6 EER Water to water, ground water (cooling mode) < 135,000 Btu/h All 59°F entering water 16.3 EER ISO 13256-2 Brine to water, ground loop (cooling mode) < 135,000 Btu/h All 77°F entering fluid 12.1 EER Water to air, water loop (heating mode) < 135,000 Btu/h (cooling capacity) 68°F entering water 4.3 COP H Water to air, ground water (heating mode) < 135,000 Btu/h (cooling capacity) 50°F entering water 3.7 COP H ISO 13256-1 Brine to air, ground loop (heating mode) < 135,000 Btu/h (cooling capacity) 32°F entering fluid 3.2 COP H Water to water, water loop (heating mode) < 135,000 Btu/h (cooling capacity) 68°F entering water 3.7 COP H ISO 13256-1 Water to water, ground water (heating mode) < 135,000 Btu/h (cooling capacity) 50°F entering water 3.1 COP H ISO 13256-2 Brine to water, ground loop (heating mode) < 135,000 Btu/h (cooling capacity) 32°F entering fluid 2.5 COP H ISO 13256-2 For SI: 1 British thermal unit per hour = 0.2931 W, °C = [(°F) - 32]/1.8. a Chapter 6 contains a complete specification of the referenced standards, which include test procedures, including the reference year version of the test procedure. b Single-phase, U.S. air-cooled heat pumps less than 19 kW are regulated as consumer produces by DOE 10 C.F.R. 430. SCOPC, SCOP2C, SCOPH and SCOP2H values for single-phase products are set by the U.S. DOE. c This table is a replica of ASHRAE 90.1 Table 6.8.1-15 Electrically Operated Water-Source Heat Pumps — Minimum Efficiency Requirements. Table C403.3.2(15) Heat-Pump and Heat Recovery Chiller Packages—Minimum Efficiency Requirements g,h,i,j,k For SI: °C = [(°F) - 32]/1.8. a Chapter 6 contains a complete specification of the referenced standards, which include test procedures, including the reference year version of the test procedure. b Cooling-only rating conditions are standard rating conditions defined in AHRI 550/590, Table 1. c Heating full-load rating conditions are at rating conditions defined in AHRI 550/590, Table 1. d For water-cooled heat recovery chillers that have capabilities for heat rejection to a heat recovery condenser and a tower condenser, the COPHR applies to operation at full load with 100 percent heat recovery (no tower rejection). Units that only have capabilities for partial heat recovery shall meet the requirements of Table C403.3.2(3). e Outdoor air entering dry-bulb (db) temperature and wet-bulb (wb) temperature. f Source-water entering and leaving water temperature. g This table is a replica of ASHRAE 90.1 Table 6.8.1-16 Heat-Pump and Heat Recovery Chiller Packages — Minimum Efficiency Requirements. h AHRI ratings are not required for equipment sizes larger than those covered by the test standard. i Air-to-water heat pumps that are configured to operate only in heating and not in cooling only need to comply with the minimum heating efficiencies. j Units that are both an air-to-water heat pump and a heat recovery chiller are required to comply with either the applicable air source efficiency requirements or the heat recovery chiller requirements but not both. k Heat pumps and heat recovery chillers are only required to comply with one of the four leaving heating water temperature criteria. The leaving heater water temperature criteria that are closest to the design leaving water temperature shall be utilized. Table C403.3.2(16) Ceiling-Mounted Computer-Room Air Conditioners — Minimum Efficiency Requirements b Equipment Type Standard Model Net Sensible Cooling Capacity Minimum Net Sensible COP Rating Conditions Return Air (dry-bulb/dew point) Test Procedure a Air cooled with free air discharge condenser Ducted < 29,000 Btu/h 2.05 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.02 ≥ 65,000 Btu/h 1.92 Nonducted < 29,000 Btu/h 2.08 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.05 ≥ 65,000 Btu/h 1.94 Air cooled with free air discharge condenser with fluid economizer Ducted < 29,000 Btu/h 2.01 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.97 ≥ 65,000 Btu/h 1.87 Nonducted < 29,000 Btu/h 2.04 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.00 ≥ 65,000 Btu/h 1.89 Air cooled with ducted condenser Ducted < 29,000 Btu/h 1.86 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.83 ≥ 65,000 Btu/h 1.73 Nonducted < 29,000 Btu/h 1.89 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.86 ≥ 65,000 Btu/h 1.75 Air cooled with fluid economizer and ducted condenser Ducted < 29,000 Btu/h 1.82 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.78 ≥ 65,000 Btu/h 1.68 Nonducted < 29,000 Btu/h 1.85 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.81 ≥ 65,000 Btu/h 1.70 Water cooled Ducted < 29,000 Btu/h 2.38 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.28 ≥ 65,000 Btu/h 2.18 Nonducted < 29,000 Btu/h 2.41 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.31 ≥ 65,000 Btu/h 2.20 Water cooled with fluid economizer Ducted < 29,000 Btu/h 2.33 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.23 ≥ 65,000 Btu/h 2.13 Nonducted < 29,000 Btu/h 2.36 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.26 ≥ 65,000 Btu/h 2.16 Glycol cooled Ducted < 29,000 Btu/h 1.97 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.93 ≥ 65,000 Btu/h 1.78 Nonducted < 29,000 Btu/h 2.00 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.98 ≥ 65,000 Btu/h 1.81 Glycol cooled with fluid economizer Ducted < 29,000 Btu/h 1.92 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.88 ≥ 65,000 Btu/h 1.73 Nonducted < 29,000 Btu/h 1.95 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.93 ≥ 65,000 Btu/h 1.76 Equipment Type Standard Model Net Sensible Cooling Capacity Minimum Net Sensible COP Rating Conditions Return Air (dry-bulb/dew point) Test Procedure a Air cooled with free air discharge condenser Ducted < 29,000 Btu/h 2.05 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.02 ≥ 65,000 Btu/h 1.92 Nonducted < 29,000 Btu/h 2.08 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.05 ≥ 65,000 Btu/h 1.94 Air cooled with free air discharge condenser with fluid economizer Ducted < 29,000 Btu/h 2.01 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.97 ≥ 65,000 Btu/h 1.87 Nonducted < 29,000 Btu/h 2.04 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.00 ≥ 65,000 Btu/h 1.89 Air cooled with ducted condenser Ducted < 29,000 Btu/h 1.86 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.83 ≥ 65,000 Btu/h 1.73 Nonducted < 29,000 Btu/h 1.89 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.86 ≥ 65,000 Btu/h 1.75 Air cooled with fluid economizer and ducted condenser Ducted < 29,000 Btu/h 1.82 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.78 ≥ 65,000 Btu/h 1.68 Nonducted < 29,000 Btu/h 1.85 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.81 ≥ 65,000 Btu/h 1.70 Water cooled Ducted < 29,000 Btu/h 2.38 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.28 ≥ 65,000 Btu/h 2.18 Nonducted < 29,000 Btu/h 2.41 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.31 ≥ 65,000 Btu/h 2.20 Water cooled with fluid economizer Ducted < 29,000 Btu/h 2.33 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.23 ≥ 65,000 Btu/h 2.13 Nonducted < 29,000 Btu/h 2.36 ≥ 29,000 Btu/h and < 65,000 Btu/h 2.26 ≥ 65,000 Btu/h 2.16 Glycol cooled Ducted < 29,000 Btu/h 1.97 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.93 ≥ 65,000 Btu/h 1.78 Nonducted < 29,000 Btu/h 2.00 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.98 ≥ 65,000 Btu/h 1.81 Glycol cooled with fluid economizer Ducted < 29,000 Btu/h 1.92 75°F/52°F (Class 1) AHRI 1360 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.88 ≥ 65,000 Btu/h 1.73 Nonducted < 29,000 Btu/h 1.95 ≥ 29,000 Btu/h and < 65,000 Btu/h 1.93 ≥ 65,000 Btu/h 1.76 For SI: 1 British thermal unit per hour = 0.2931 W, °C = [(°F) – 32]/1.8, COP = (Btu/h × hp)(2,550.7). a Chapter 6 contains a complete specification of the referenced standards, which include test procedures, including the reference year version of the test procedure. b This table is a replica of ASHRAE 90.1 Table 6.8.1-17 Ceiling-Mounted Computer-Room Air Conditioners—Minimum Efficiency Requirements.
WAC 51-11C-403329: WAC 51-11C-403329. Tables C403.3.2(9) through C403.3.2(16) — HVAC equipment minimum efficiency requirements | Justis AI