32 Ill. Adm. Code 346.290
Radiation Monitors
Section 346.290 Radiation Monitors
a) Irradiators
with automatic product conveyor systems shall have a radiation monitor with an
audible alarm located to detect loose radioactive sources that are carried
toward the product exit. If the monitor detects a source, an alarm shall sound
and product conveyors shall stop automatically and the sources shall become
fully shielded. The alarm shall be capable of alerting personnel in the
facility who are prepared to summon assistance. Underwater irradiators in
which the product moves within an enclosed stationary tube are exempt from the
requirements of this subsection.
b) Underwater
irradiators that are not in a shielded radiation room shall have a radiation
monitor over the pool to detect abnormal radiation levels. The monitor shall
have an audible alarm and a visible indicator at entrances to the personnel
access barrier around the pool. The audible alarm may have a manual shut-off.
The alarm shall be capable of alerting personnel who are prepared to respond
promptly.