32 Ill. Adm. Code 346.310
Control of Source Movement
Section 346.310 Control of Source Movement
a) The
mechanism that moves the source of a panoramic irradiator shall require a key
to actuate. Actuation of the mechanism shall cause an audible signal to
indicate that the sources are leaving the shielded position. Only one key may
be in use at any time, and only operators or facility management may possess
it. The key shall be attached to a portable radiation survey meter by a chain
or cable. The lock for source control shall be designed so that the key may
not be removed if the sources are in an unshielded position. The personnel
entrance door or barrier to the radiation room shall require the same key.
b) The
console of a panoramic irradiator shall have a source position indicator that
indicates when the sources are in the fully shielded position, when the sources
are in transit and when the sources are exposed.
c) The
control console of a panoramic irradiator shall have a control that promptly
returns the sources to the shielded position.
d) Each
control for a panoramic irradiator shall be clearly marked as to its function.