35 Ill. Adm. Code 370.440
Alarm Systems
Section 370
Section 370.440 Alarm
Systems
Alarm systems shall be provided
for pumping stations. The alarm shall be activated in cases of power failure,
pump failure, unauthorized entry, or any cause of pump station malfunction.
Pumping station alarms shall be telemetered to a municipal facility that is
manned 24 hours a day. If such a facility is not available and a 24-hour
holding capacity is not provided, the alarm shall be telemetered to city
offices during normal working hours and to the home of the person(s) in
responsible charge of the lift station during off-duty hours. Audio-visual
alarm systems with a self-contained power supply may be acceptable in some
cases in lieu of the telemetering system outlined above, depending upon
location, station holding capacity and inspection frequency.