77 Ill. Adm. Code 330.3940
Exit Facilities and Subdivision of Floor Areas
Section 330
Section 330.3940Â Exit
Facilities and Subdivision of Floor Areas
Every existing facility shall
meet the following requirements:
a)Â Â Â Â Â Â Â Â Each floor used for the housing of residents shall have at
least two approved exits which are well separated and provided in the most
accessible locations. (A, B)
b)Â Â Â Â Â Â Â Â All future fire escapes shall be of fire resistive
construction. (B)
c)Â Â Â Â Â Â Â Â All corridors and passageways to be used as a means of
horizontal exit shall be at least three feet wide. (B)
d)Â Â Â Â Â Â Â Â Wherever an existing or future stairway, balcony landing,
platform, slide escape, or runway of a fire escape stairway is located ten feet
or less from a window or doorway, such window or door shall be provided with
wired glass. (B)
e)Â Â Â Â Â Â Â Â All exits, passageways, and exits through rooms shall be kept
free of any item that would obstruct the exit route. (B)
f)Â Â Â Â Â Â Â Â All corridors and passages to be used as a means of horizontal
exit, or part of a means of exit, shall not lead through any room or space used
for a purpose that may obstruct free passage. (B)