675 IAC 15-2-101
675 IAC 15-2-101 Interconnection of multiple section mobile residential structures
Cite as Ind. Admin. Code tit. 675, r. 15-2-101
Sec. 101. (a) Fixed-type Wiring. Approved and listed fixed-type wiring methods shall be used to join portions of a circuit which must be
electrically joined which are located in adjacent sections of mobile structures after the structure is installed on its support foundation. The circuits
junction shall be accessible for disassembly when the structure is prepared for relocation.
(b) Disconnecting Means. Multiple section mobile structures not having permanently installed feeders, and which are to be moved from
one (1) location to another shall be permitted to have disconnecting means with branch-circuit protective equipment in each unit when so located
that after assembly or joining together of units, they shall not be interconnected on either the live side or the load side, except that the grounding
means shall be electrically interconnected.