10 CSR 60-4.050
Maximum Turbidity Levels and Monitoring Requirements and Filter Backwash Recycling
PURPOSE: This rule establishes maximum
contaminant levels and monitoring requirements for turbidity.
(1) Applicability. This rule applies to all public water systems that use surface water or
ground-water under the direct influence of
surface water.
(2) Enhanced Turbidity Requirements.
(A) Maximum Turbidity Levels.
1. Turbidity must be equal to or less
than 0.3 turbidity units in at least ninety-five
percent (95%) of the measurements taken
each month; and
2. There must be no more than one (1)
turbidity unit in any one (1) measurement.
(B) The frequency of sampling shall be as
set forth in 10 CSR 60-4.080(3).
(C) Reporting to the Department.
1. If at any time the turbidity exceeds
one (1) nephelometric turbidity unit (NTU)
in representative samples of filtered water in
a system using conventional filtration treatment or direct filtration, the system must
inform the department as soon as possible,
but no later than the end of the next business
day.
2. If at any time the turbidity in representative samples of filtered water exceeds
the maximum level set by the department
under subsection (2)(F) of this rule for filtration technologies other than conventional filtration treatment, the system must inform the
department as soon as possible, but no later
than the end of the next business day.
(D) Filtration Sampling Requirements for
Surface Water Systems
1. A public water system using surface
water or groundwater under the direct influence of surface water that provides conventional filtration treatment must conduct continuous monitoring of turbidity for each individual filter using an approved method in 10
CSR 60-5.010 and must calibrate turbidimeters using the procedure specified by the
manufacturer. Systems must record the
results of individual filter monitoring every
fifteen (15) minutes.
2. If there is a failure in the continuous
turbidity monitoring equipment, the system
must conduct grab sampling every four (4)
hours in lieu of continuous monitoring, until
the turbidimeter is repaired and back on-line.
A system has a maximum of five (5) working
days after failure in the continuous monitoring equipment to repair the equipment before
the system is in violation. With department
approval, systems serving less than ten thousand (10,000) people may be granted up to
fourteen (14) days to repair the equipment
before the system is in violation.
(E) Lime Softening.
1. A system that uses lime softening may
acidify representative samples prior to analysis using a protocol approved by the department.
2. Systems that use lime softening may
apply to the department for alternative
exceedance levels for the levels specified in
10 CSR 60-7.010(6)(B) if they can demonstrate that higher turbidity levels in individual filters are due to lime carryover only and
not due to degraded filter performance.
(F) Filtration Technologies Other Than
Conventional Filtration Treatment.
1. A public water system may use a filtration technology other than conventional
filtration if it demonstrates to the department,
using pilot plant studies or other means, that
the alternative filtration technology, including
direct filtration, in combination with disinfection treatment that meets the requirements
of 10 CSR 60-4.055, consistently achieves
99.9 percent removal and/or inactivation of
Giardia lamblia cysts and 99.99 percent
removal and/or inactivation of viruses, and
ninety-nine percent (99%) removal of
Cryptosporidium oocysts, and the department
approves the use of the filtration technology.
2. For each approval, the department
will set turbidity performance requirements
that the system must meet at least ninety-five
percent (95%) of the time and that the system
may not exceed at any time at a level that consistently achieves 99.9 percent removal
and/or inactivation of Giardia lamblia cysts,
99.99 percent removal or inactivation of
viruses, or both, and 99 percent removal of
Cryptosporidium oocysts.
(3) Filter Backwash Recycling.
(A) Applicability. Any water treatment
plant proposed for construction or major
modification for a surface water or groundwater under the direct influence of surface
water or direct filtration treatment and that
will recycle spent filter backwash water,
thickener supernatant, or liquids from dewatering processes must be designed to meet the
filter backwash recycling requirements of this
section.
(B) Reporting. A system must notify the
department in writing if the system recycles
spent filter backwash water, thickener supernatant, or liquids from dewatering processes.
This notification must include, at a minimum, the following information:
1. A plant schematic showing the origin
of all flows which are recycled (including, but
not limited to, spent filter backwash water,
thickener supernatant, and liquids from
dewatering processes), the hydraulic conveyance used to transport them, and the location where they are reintroduced back into
the treatment plant; and
2. Typical recycle flow in gallons per
minute (gpm), the highest observed plant
flow experienced in the previous year (gpm),
design flow for the treatment plant (gpm),
and department-approved operating capacity
for the plant where the department has made
such determinations.
(C) Treatment Technique Requirement.
Any system that recycles spent filter backwash water, thickener supernatant, or liquids
from dewatering processes must return these
flows through the processes of a systemโs
existing conventional or direct filtration system or at an alternate location approved by
the department.
(D) Record Keeping. The system must collect and retain on file recycle flow information for review and evaluation by the department. This information shall include, but may
not be limited to:
1. A copy of the recycle notification and
information submitted to the department
under subsection (3)(B) of this rule;
2. A list of all recycle flows and the frequency with which they are returned;
3. Average and maximum backwash
flow rate through the filters and the average
and maximum duration of the filter backwash
process in minutes;
4. Typical filter run length and a written
summary of how filter run length is determined;
5. The type of treatment provided for the
recycle flow; and
6. Data on the physical dimensions of
the equalization and/or treatment units, typical and maximum hydraulic loading rates,
type of treatment chemicals used and average
dose and frequency of use, and frequency at
which solids are removed, if applicable.
AUTHORITY: section 640.100, RSMo 2016.*
Original rule filed May 4, 1979, effective
Sept. 14, 1979. Amended: Filed April 14,
1981, effective Oct. 11, 1981. Amended: Filed
July 12, 1991, effective Feb. 6, 1992.
Amended: Filed Feb. 1, 1996, effective Oct.
30, 1996. Amended: Filed Dec. 15, 1999,
effective Sept. 1, 2000. Amended: Filed Jan.
16, 2002, effective Nov. 30, 2002. Amended:
Filed March 17, 2003, effective Nov. 30,
2003. Amended: Filed June 13, 2018, effective Feb. 28, 2019.
*Original authority: 640.100, RSMo 1939, amended 1978,
1981, 1982, 1988, 1989, 1992, 1993, 1995, 1996, 1998,
1999, 2002, 2006, 2012, 2014.