NDAC 33.1-18-01-06
General well construction requirements
Cite as N.D. Admin. Code ยง 33.1-18-01-06
1.
Construction water. Water used in the drilling process shall be obtained from a source which
will not result in contamination of the well. Chlorination of the water with an initial dosage of
not less than fifty milligrams per liter (one gallon [3.78 liters] of laundry bleach or 0.6 pounds
[1.32 kilograms] of calcium hypochlorite per one thousand gallons [3.78 kiloliters] of drilling
water) is recommended.
Waters from surface sources must be chlorinated with a minimum dosage of one hundred
milligrams per liter (two gallons [7.56 liters] of laundry bleach or 1.2 pounds [2.64 kilograms] of
calcium hypochlorite per one thousand gallons [3.78 kiloliters] of drilling water).
2.
Ferrous well casing.
a.
General. Casing and liner pipe of wrought iron or steel through ten inches
[25.4 centimeters] in diameter shall be prime pipe meeting current American society for
testing and materials schedule 40, or equivalent specifications. Larger diameter pipes
shall have a minimum wall thickness of three hundred seventy-five thousandths of an
inch [0.952 centimeter].
All casing shall have additional thickness and weight if standard thickness is not
considered sufficient to assure reasonable life expectancy of the well or be capable of
withstanding forces to which they are subjected.
b.
Drive shoe. Pipe that is to be driven shall be equipped with a drive shoe or other device
approved by the department.
c.
Joints. Casing and liner pipe joints shall be properly welded or threaded.
3.
Nonferrous well casing.
a.
General. Pipe other than wrought iron or steel must be adaptable to the stresses to which
they will be subjected during and after installation and to the corrosiveness of the water.
b.
Thermoplastic well casing. Thermoplastic well casing shall conform with American
society for testing and materials specification F480-81 or latest revision as follows:
(1)
Minimum standard dimension ratio shall be twenty-one for casings less than sixteen
inches [40.64 centimeters] in diameter. Minimum standard dimension ratio shall be
twenty-six for casings sixteen inches [40.64 centimeters] in diameter or larger.
Casings with a lower standard dimension ratio (additional thickness) must be used
when the minimum standard dimension ratio is not capable of withstanding the
stresses encountered during and after installation.
(2)
Minimum pipe stiffness shall be two hundred twenty-four pounds/foot [inch . inch]
(kiloneutron/[meter . meter]) when tested according to section 5.4.1 of American
society for testing and materials specification F480.
(3)
All casing five inches [12.7 centimeters] and larger shall be tested for impact
resistance and meet or exceed IC-1 impact classification according to section 6.5
and table 6 of American society for testing and materials specification F480.
c.
Other materials. Other well casing materials that may be proposed shall carry the seal of
the national sanitation foundation and be approved in writing by the department prior to
installation.
4.
Packers. Packers shall be of a material that will not impart taste, odors, toxic substances, or
bacterial contamination to the water in the well.
5.
Screens. Screens must be constructed of corrosion-resistant material and sufficiently strong
to withstand stresses encountered during and after installation. Screen slot openings, screen
length, and screen diameter should be sized and designed to provide sufficient open area
consistent with strength requirements to transmit sand-free water at a capacity at least equal
to one and one-half times the capacity of water anticipated. Screen slot size should be based
on sieve analysis of formation samples.
Screens should be installed so that exposure above pumping level will not occur. A screen
must be attached or connected to the casing by a threaded, solvent-welded, or welded joint or
by threaded fasteners or a nontoxic packer. Solvent-welded joints should not impart taste,
odors, toxic substances, or bacterial contamination to the water in the well.
6.
Filter pack. Material used as a filter pack shall be sand or sand and gravel that is free of
foreign material, properly sized, washed, and then disinfected prior to or during placement.
Provisions for prevention of leakage of grout into the filter pack or screen shall be provided.
7.
Well development. Every well shall be developed prior to yield and drawdown testing. Well
development includes procedures to apply physical energy to the screen and aquifer
formation adjacent to the well. After development, the well should produce sand-free water at
a capacity at least equal to one and one-half times the capacity of water anticipated.
8.
Yield and drawdown test. Every well should be tested for yield and drawdown. The test
method to be followed should be clearly outlined in the specifications. The test pump should
have a maximum capacity at least equal to one and one-half times the capacity of water
anticipated. The test pump should be able to operate continuously until the rate of decline of
the pumping water level has stabilized. Test data to be recorded should include:
a.
Static water level.
b.
Pumping rate.
c.
Drawdown during test.
d.
Recovery water levels.
e.
Depth of pump setting.
Duration of the test shall be determined with due consideration given to pumping of sand,
clarity of water pumped, and the obtaining of a representative sample of water for chemical
analysis.
9.
Chemical conditioning. When chemical treatment of a public well is proposed, the method of
conditioning shall be included in the specifications. The equipment, chemicals, and inhibitors
to be used, the method of testing for chemical residuals, and the disposal of waste shall be
indicated.
10.
Grouting requirements.
a.
Neat cement grout. The mixture should consist of one sack of cement (ninety-four
pounds [42.64 kilograms]) to not more than six gallons [22.71 liters] of clean water.
Bentonite additives up to five pounds [2.27 kilograms] per sack of cement to increase
fluidity may be used. Pozzuolana additives up to thirty-three pounds [14.97 kilograms]
per sack of cement may be used.
b.
Heat of hydration. Care must be used when grouting thermoplastic well casing with neat
cement grout. Heat caused by hydration during curing of the cement may cause
weakening of the well casing. High peak temperatures may be minimized by adding sand
or bentonite clay to the neat cement grout mixture to increase the curing time. The
amount of sand or bentonite clay added to the neat cement grout may not exceed five
pounds [2.27 kilograms] per sack of cement.
c.
High-solids bentonite clay grout. The mixture must consist of not less than three pounds
[1.36 kilograms] of bentonite clay per gallon [3.79 liters] of clean water.
High-solids bentonite clay grout, bentonite chips, or bentonite tablets must be
commercially prepared specifically for the purpose of sealing water wells. The use of
bentonite drilling fluids as a grouting material is not permitted.
d.
Grouting guides. Casing that is to be grouted in the drill hole or annular opening shall be
provided with sufficient guides welded to the casing to permit the unobstructed flow and
uniform thickness of grout.
e.
Grout application. Grout material must be positively and accurately placed to fill all voids.
All grouting should be performed by adding the mixture, from the bottom of the annular
space upward, in one continuous operation, until the annular space is filled. Sufficient
annular opening shall be provided to permit a minimum of one and one-half inches
[3.81 centimeters] of grout around the casing, including couplings, if used.
Bentonite chips or tablets may be added from the top of the annular space to a maximum
depth of thirty feet [9.1 meters] provided the grout material is positively and accurately
placed to fill all voids and hydrated after placement.
11.
Plumbness and alignment. Every well shall be tested for plumbness and alignment upon
completion of construction. The casing shall be sufficiently plumb so as not to interfere with
the installation and operation of the pump. (See recommended procedures in the appendix to
this chapter.)
12.
Well construction data. The water well contractor shall provide the North Dakota board of
water well contractors with an accurate record of well construction data. Drill cuttings should
be obtained at five-foot [1.52-meter] intervals, and at all pronounced changes in formation.
Well construction data shall include an accurate record of the drill hole diameters and depths,
assembled order of size and length of casings and liners, grouting depths, formations
penetrated, water levels, location of blast shots, and pumping tests. Well construction report
forms are available from the North Dakota board of water well contractors.
13.
Upper terminal of well. The casing or pitless unit for all ground water sources shall project
not less than twelve inches [30.48 centimeters] above the final ground elevation, the well
cover slab, or pumphouse floor.
Sites subject to flooding shall have the top of the protective casing, pitless unit, the cover of
every dug well, and the floor of the pumphouse at least two feet [60.96 centimeters] above the
highest-known flood elevation and be surrounded by earthfill.
14.
Capping. The well must be protected during construction. A properly fitted cap designed for
the type of well casing installed shall be used to protect the well from surface contamination
until pumping equipment is installed.
15.
Bacteriological and chemical quality of water. Every new, modified, or reconditioned
ground water source shall be thoroughly cleaned and disinfected after the completion of
construction and again after the permanent pump has been installed. The certified water well
contractor or pump and pitless unit installer in charge during well construction and pump
installation shall advise the well owner that one or more water samples from the source should
be submitted to an approved laboratory for bacteriological analysis and that the well should
not be placed into service until satisfactory bacteriological results are obtained.
Wells intended for use by a public water system shall be sampled for bacteriological analysis
and the following chemicals and not placed into service until the results are deemed by the
department to comply with the primary drinking water standards established under the Safe
Drinking Water Act: antimony, arsenic, barium, beryllium, cadmium, chromium, copper,
cyanide, fluoride, lead, mercury, nickel, combined nitrate/nitrite, selenium, thallium,
manganese, and sulfate. When it is established that the ground water is subject to continuous
or intermittent contamination, or for public water systems that the ground water is under the
direct influence of surface water, provisions for continuous disinfection will be required.
16.
Chemical quality of water. Every new, modified, or reconditioned ground water source
should be examined for its chemical characteristics by tests of a representative sample in a
department or other approved laboratory. The samples should be collected and tested as soon
as practical.
17.
Water level measurement. Provisions should be made for periodic measurement of the static
and pumping water levels in the completed well. The installation shall be made in such
manner as to prevent the entrances of foreign material.
18.
Water supply wells, geothermal ground water and return wells, and special purpose
water wells. All wells designed as water supply wells, geothermal ground water or return
wells, or special purpose water wells shall be constructed in accordance with this chapter.
Each well shall be protected at its upper terminal to preclude the entrance of foreign materials.
19.
Abandoned wells. Any abandoned water wells, including test wells, uncompleted wells, and
completed wells shall be sealed by restoring, as far as possible, the controlling geological
conditions which existed before the wells were drilled.
Sealing of wells results in:
a.
Elimination of physical hazards.
b.
Prevention of contamination of ground water.
c.
Conserving yield and hydrostatic head of aquifers.
d.
Prevention of intermingling of desirable and undesirable waters.
Wherever feasible, the wells should be filled with concrete grout or other approved materials.
(Note: recommended grouting procedures are in the appendix to this chapter.)
At no time shall any sewage or other contaminated or toxic materials be discharged into an
abandoned well.
20.
Organic polymers. The use of biodegradable organic polymers as a drilling fluid additive has
resulted in persistent microbiological contamination of ground water supplies. Organic
polymers shall be used only when approved in writing by the department for a specific well
construction project.